INSTALL HANDLES
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the
ADAPTER (1) without a spline is facing up. See figure "A". Tighten
STEM SCREW (3) to secure ADAPTER (1).
Find correct position of LEVER HANDLE ASSEMBLY (4) or CROSS
HANDE ASSEMBLY (5) by adjusting male teeth on ADAPTER (1) to
female teeth in HANDLE (4, 5).
Thread LEVER HANDLE ASSEMBLY (4) or CROSS HANDE ASSEMBLY
(5) onto DECK ADAPTER (6) until snug against mounting surface.
4
Figure "A"
SPLINE END DOWN
WATER SUPPLY CONNECTIONS
NOTE: FLEXIBLE SUPPLIES ARE NOT INCLUDED AND HAVE TO BE
PURCHASED SEPARATELY.
Connect water supplies to FAUCET (1) with 1/2" IPS
FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply
when bending. Use tubing cutter to cut to proper length.
FINISH DRAIN INSTALLATION
Position BIDET fixture and secure to floor.
Insert lift rod into lift rod guide.
Position EXTENSION ROD (1) onto POP-UP ROD (2) and tighten
THUMBSCREW (3).
Remove one end of CLIP (4) from PIVOT ROD (7) by squeezing ends
together while sliding.
Insert PIVOT ROD (7) into second or third hole in EXTENSION ROD (1)
and reassemble CLIP (4). (EXTENSION ROD (1) may need to be bent.)
Adjust STOPPER height by repositioning EXTENSION ROD (1) and
tightening THUMBSCREW (3).
Using metal TAILPIECE (5), make connection to the TRAP (6).
THREAD ON
5
TOP
DIVERTER KNOB:
Install HANDLE ADAPTER (8) onto valve stem.
Push DIVERTER KNOB (7) onto HANDLE ADAPTER (8).
Install RING (9) onto DIVERTER KNOB (7) and tighten
with HANDLE SCREW (10).
Press on KNOB CAP (11).
TO DECK
ADAPTER
1
3
2
6
1
Hot
11
10
9
7
8
VALVE STEM
2
3
Cold
2
3
1
5
6
COUPLING NUT
FERRULE
1
7
4

Advertisement