QuickSpecs
Configuration
Power Distribution Units
Power Distribution Units
Power Distribution Units
Power Distribution Units
60 amp Power Distribution Unit-
60 amp Power Distribution Unit-
60 amp Power Distribution Unit-
60 amp Power Distribution Unit-
AF916A (NA/JPN) and AF917A (International)-supported in 10K G2 rack
E7683A (US) and E7684A (International)-supported in Rack System E
Customers who prefer the fewest higher amperage connections from their AC line current source to the
HP 9000 rp7440 Server can use the 60 amp power distribution unit (PDU). The AF916A and AF917A
PDUs contain 12 C19 outlets. The E7683A and E7684A PDUs contain 8 C19 outlets. For more details
on PDUs, please see PDU sales collateral. This PDU is sold separately and can be ordered with any HP
server solution.
The maximum amperage is 60 amps through the entire PDU and 20 amps per breaker. Both limits must
be met. Each 60 amp PDU can support up to four HP 9000 rp7440 servers if the PDU is not mounted in
the same rack. Up to three HP 9000 rp7440 servers can be supported if the PDU is mounted within the
same rack
For redundant power inputs, the second set of cords is added. If the second PDU is plugged into a
second grid this configuration provides protection against:
Losing power from a single power grid
Accidental tripping of one or two circuit breakers
Accidental disconnect of a single PDU power cord
Accidental disconnect of up to four (two from each system) system power cords
30 amp Power Distribution Unit-
30 amp Power Distribution Unit-
30 amp Power Distribution Unit-
30 amp Power Distribution Unit-
252663 D74 (NA/JPN) and 252663 B33 (International)-supported for 10K G2 rack
E7681A (North America/JPN) and E7682A (International)-supported with Rack System E
A 30 amp Power Distribution Unit (PDU) is also supported with HP 9000 rp7440 Server. Rack
configurations consisting of peripherals and only one HP 9000 rp7440 Server will likely be best
supported with the 30 amp PDU. This PDU is sold separately and can be ordered with any HP server
solution.
Unlike the 60 amp PDU, each 30 amp PDU can only support one HP 9000 rp7440 Server. The
following configuration guidelines apply when using the 30 amp PDU:
A0 and A1 or B0 and B1 cords should never be plugged into the same PDU
Use two 30 amp PDUs to achieve input power redundancy (plugging A0/A1 and B0/B1 into
separate PDUs).
Ordering tools will not force the purchase of a second PDU for input power redundancy. A second
PDU must be manually selected if redundant input power is desired.
DA - 12696
North America — Version 4 — March 3, 2008
HP 9000 rp7440 Server
HP 9000 rp7440 Server
HP 9000 rp7440 Server
HP 9000 rp7440 Server