24-Hour Operating Mode; Switching Program; Holiday Function - Siemens REV23 User Manual

Self-learning room temperature controller, 5 operating modes, heating / cooling functions and menu selection via roller selector
Table of Contents

Advertisement

24-hour operating mode

Example

Switching program

Example with 2 heating
periods per day

Holiday function

Siemens Building Technologies
HVAC Products
The controller generates the 24-hour operating mode from the current 24-hour pro-
gram. It automatically selects the switch-on time of the first heating / cooling period and
the switch-off time of the last heating / cooling period to generate and display a com-
plete heating / cooling period. The comfort temperature used by the controller is the
currently stored standard setpoint of the continuous operating mode
generated 24-hour operating mode is maintained until another operating mode is se-
lected.
°C
22
20
T
18
T
08
Automatically generated
24-hour operating mode
The switching program can be used as a 7-day or 24-hour switching program,
depending on programming. It is also possible to select one of the continuous operating
modes
with which the switching program is not used.
With the 7-day switching program, it is possible to program all days individually, the
working days (1-5), the weekend (6-7), or the entire week (1-7).
When a heating / cooling period is programmed, 3 different switching patterns are
available.
It is possible to select 1, 2 or 3 heating / cooling periods.
For each heating / cooling period, the start time, end time and comfort setpoint are to
be entered. In between heating / cooling periods, it is always the same economy tem-
perature setpoint that is used. This economy temperature setpoint can be adjusted on
the temperature menu.
°C
22
20
Heating
period 1
18
16
08
The holiday function is to be selected on the user menu. Set the start of the holiday
period (day of departure/
setpoint (
) during your absence. This will enable the controller to maintain the re-
quired temperature for a period of up to 99 days. Every midnight, the counter subtracts
one day.
Room Temperature Controller REV23
10
18
Current 24-hour switching program
10
18
/ day of week), the duration and the temperature
. The self-
22
h
Heating
period 2
22
h
5/12
CE1N2264en
23.04.2002

Hide quick links:

Advertisement

Table of Contents
loading