7-day room temperature controller

Advertisement

Engineering
Mounting and
installation
Preparations to
commission
the unit
Commissioning
Important:
Select operating
language
Notes
11 / 15
Siemens
Building Technologies
∂ Mount the room unit in the main living room.
∂ Select the mounting place so that the sensor can acquire the air temperature in the
room as accurately as possible and without being influenced by solar radiation or
other heat or refrigeration sources.
∂ Mounting height is approx. 1.5 m above the floor.
∂ You can mount the unit on most commercially available recessed conduit boxes or
directly on the wall.
∂ Begin installation by first attaching and wiring the base. You can mount the base on
most commercially available recessed conduit boxes or directly on the wall. Insert
the controller from top to bottom in the base.
See the operating instructions delivered with the unit for more information.
∂ Comply with all local regulations on electrical installations.
∂ Wire the remote control contact T1/ T2 separately, i.e. using a separate, screened
cable.
Warning!
No internal line protection for supply lines to external consumers.
Risk of fire and injury due to short-circuits!
∂ Adapt the line diameters as per local regulations to the rated value of the
installed overcurrent protection device.
∂ The power supply line must have an external circuit breaker with a rated current of
no more than 10 A.
∂ Set any thermostatic radiator valves to their fully open position, if present in the
reference room.
∂ Recalibrate the temperature sensor (see "Sensor calibration") if the displayed room
temperature does not match the room temperature measured.
∂ Remove the battery transit tab.
∂ The unit is ready for operation and executes a 180 second initialization period as soon
as you remove the transit tab from the battery contact. In this phase, the actuator is
driven to the basic position CLOSED.
Driving the actuator to the fully CLOSED position takes max. 150 seconds.
Reinsert the controller in the base within 30 seconds after removing the black
battery transit tab!
∂ During the above actuator initialization phase, the controller type is displayed at the
top left along with a welcome message "THANK YOU..." in all available languages.
∂ Press any button to interrupt the scrolling text. Operating language selection starts
with "ENGLISH" (factory setting). Press
operating language. Press
language.
∂ If synchronization is not yet completed after language selection, the remaining time
is counted down on the display.
Do not press any button during this time!
∂ If synchronization is complete after you select the operating language, you can
continue to set the time of day (as needed), date, comfort phases, etc..
This is a software class A controller designed for use at a normal degree of pollution.
Room temperature controller REV34..
or
until you reach the desired
or move the slider to confirm the selected operating