UNPACKING

1. Remove the unit from the carton and remove all
packing materials.
2. Remove information packet. To prevent delay
in obtaining warranty coverage, fill out and
mail in warranty card.
NOTE: If unit is equipped with optional equipment,
see ACCESSORIES section at back of this manual.

LOCATION

WARNING
For safe and proper operation, the unit must be
located the correct distance from combustible
walls and materials. If safe distances are not
maintained, discoloration or combustion could
occur. Refer to specific installation and
mounting information in this manual for proper
clearances.
WARNING
To prevent any injury or damage to the unit do
not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any
other appliance.
WARNING
To prevent combustion or damage to materials
do not install standard wattage strip heater (GR,
GRA, GRN, GRAL Series) less than 10" (254 mm)
above a non-metallic surface. Do not install high
wattage strip heater (GRH, GRAH, GRNH,
GRAHL Series) less than 13-1/2" (343 mm) above
a non-metallic surface. Do not install dual strip
heaters (GRA-XXD, GRAH-XXD, GRAL-XXD &
GRAHL-XXD Series) above non-metallic surface.
Install all non-dual strip heaters so there is a
minimum distance of 3" (76 mm) from a non-
metallic wall or adjacent surface.
CAUTION
To prevent unit failure do not add a decorative
soffit to hide a pass-through mounted Glo-Ray
Strip Heater.
To avoid any injury or damage all electrical
connections must be in accordance with local
electrical codes and any other applicable codes.
Connections should be made by a qualified,
licensed electrician.
Heat damage to countertop material such as
®
Corian
and similar products (other than
stainless steel) is not covered under the Hatco
warranty. Contact the manufacturer of the base
material for temperature limits and application
information before installing the unit.
NOTE: Contact the countertop manufacturer of the
base material for application information and
surface temperature limits before installing the unit.
Dual Mounting
Dual models ordered from the factory are shipped
with either a 3" (76 mm) or 6" (152 mm) spacer.
NOTE: When mounting units side-by-side, a space
not less than 3" (76 mm) must be maintained
between units.
NOTE: Dual models are only available with Glo-Ray
aluminum housings.
Installation of two or more single units with less
than 3" (76 mm) between housings may result in
premature failure of component parts.
When proper distances are maintained, hot foods
will be held at ideal serving temperatures without
cooking the foods beyond the point of excellence.
See Figures 10-12 for strip heater spacing
requirements.
11