SET
6:35
SET TIME
6:35
SET TIME
RETURN TO ROTATING DISPLAY
WATER HARDNESS
20
SET
DAYS BETWEEN REGEN
14
SET
REGEN TIME HOUR
2:00
AM
SET
REGEN TIME MINUTES
2:00
SET
RETURN TO ROTATING DISPLAY
8
Step 1
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using  or  buttons. AM/PM
toggles after 12. Press NEXT to go to step 3.
PM
Step 2
Step 3 - Current Time (minutes): Set the minutes of day using  or  buttons. Press
NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - Lithium battery on circuit board provides up to 2 years of time clock backup
during power outages. If the power is out when battery is depleted, only time of day needs
to be reset, all other values are stored in non-volatile memory. When time of day is flash-
ing, replace lithium coin type 2032 battery.
PM
Step 3
Battery back-up feature will be activated after 24 hours of power.
Do not forget to reset for daylight savings time.
Figure 9
insTaller DisplaYs/seTTinGs
Step 1I
Step 1I - Press NEXT and  simultaneously for 3 seconds.
Step 2I - Hardness: Set the amount of total compensated hardness in grains (hard-
ness as calcium carbonate) per gallon using  or  buttons. The factory setting is
20 with value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon
Step 2I
should be increased if soluble iron needs to be reduced.
for each ppm of iron present. If this display shows nA -, then system is set-up in "filter"
GR
mode or "AUTO" is not selected in softener system setup. (See page 32). Press
NEXT to go to Step 3. Press REGEN to exit Installer Displays/Settings.
Step 3I - Day Override: This sets the number of days between regenerations. If
value set to "oFF" regeneration initiation is based solely on gallons used. If value is
set as a number (allowable range from 1 to 28) a regeneration initiation will be called
Step 3I
for on that day even if sufficient number of gallons were not used to call for a regen-
eration. Set Day Override using  or  buttons: Factory setting is 14 days.
• number of days between regeneration (1 to 28); or
• "oFF"
See pages 9-12, for more detail on softener setup. Press NEXT to go to step 4.
Press REGEN to return to previous step.
Step 4I
Step 4I - Regeneration Time (hour): Set the hour of day for regeneration using  or
 buttons. AM/PM toggles after 12. The factory setting time is 2:00 a.m. This display
will show "REGEN" "IMMEDIATE ON zERO GAL" if "Immediate" is selected on Step
12 of softener set-up. See page 32. Press NEXT to go to step 5. Press REGEN to
return to previous step.
Note: When installing this unit as part of a multi unit parallel system the regen time of
Step 5I
AM
day must be adjusted to prevent multiple units from regenerating at the same time.
Step 5I - Regeneration Time (minutes): Set the minutes of day for regeneration
using  or  buttons. This display will not be shown if system is set for immediate
regeneration. Press NEXT to exit Installer Displays/Settings. Press REGEN to return
to previous step.
Figure 10a
seT TiMe Of DaY
=  Up Arrow
=  Down Arrow
=  Up Arrow
=  Down Arrow
Add 3 grains of hardness