STEP 12 S – Set Regeneration Time Options using the  or  button. If value is set to:
Step 12S
• "DELAY" means regeneration will occur at the preset time; (page 8, step 4)
• "IMMEDIATE" means regeneration will occur immediately when the gallons capacity reaches 0
(zero); or
• "DELAY + IMMEDIATE" means regeneration will occur at one of the following:
- the preset time when the gallons capacity falls below the reserve or the specified number of days
between regenerations is reached, whichever comes first; or
- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
-Delay + Immediate is NOT available if control is programmed as a twin alternating configuration.
Selecting "DELAY" will result in an immediate alternation upon capacity depletion but regeneration
is delayed to preset time.
See page 32 for more options. Factory Setting is DELAY + IMMEDIATE. Press NEXT to go to
Step 13S. Press REGEN to return to previous step.
Step 13S
Step 14S
10
MIN
Step 15S
MIN
Step 16S
Step 17S
1
GAL
Step 18S
MIN
Step 19S
GAL
STEP 13 S – Set Relay to activate by Time, Gallons, Regen Gallons, Lockout,
Off or Service Alarm by using  or  buttons. A relay can be used to operate a
chemical feed pump or solenoid, etc. The choices are:
• Relay Triggered on Time - Relay activates after set number of minutes after start
of regeneration. Start of regeneration is defined by first backwash cycle, dn
brine or up brine, whichever is first. Relay deactivates after set time. Press
NEXT for programming.
• Relay Triggered on Gallons - Relay activates every set number of gallons
while in service and deactivates after set time. Press NEXT to go to 17S for
programming.
• Relay Triggered on Regen Gallons - Relay activates after set number of gallons
in service or gallons used during regeneration and de-activates after set time
or when meter stops registering flow, whichever comes first. Press NEXT to
go to 20S for programming.
• Service Alarm - Relay activates on service alarm setting: gallons, time or both,
see step 22S.
• Relay Triggered for Lockout - Relay is activated at set number of minutes into
regeneration including negative numbers to energize relay prior to regenera-
tion starting. Selection of energizing relay for complete regeneration cycle is
available by selecting REGEN for time setting, see step 23S.
• Off - If off is selected, Steps 14S – 22S will not be shown. Factory setting
= OFF. Press NEXT to go to step 14S or other selection for relay settings, or
23S if OFF selected.
STEP 14 S – If off was selected in previous step, this screen does not appear.
Time chosen to Activate Relay, use up and down arrows to set # of minutes
AFTER START OF REGEN to activate relay. Start of regeneration is defined as
first Backwash or Regenerant Draw mode. Time Range = 1 – 500 minutes. Press
NEXT to go to Step 15S.
STEP 15 S – Use Up and Down arrows to set duration of relay activation in minutes.
Range is 0:01 (1 second) to 500:00 (500 minutes). Press NEXT to go to Step 26S.
Press REGEN to return to previous step.
STEP 16 S – Gallons chosen to activate relay. If Off or Time was selected in
previous steps, this screen does not appear. Press NEXT for trigger programming.
STEP 17 S – Use up and down arrows to set # of gallons per relay activation.
Range = 0.1 – 20,000 gallons. Press NEXT for Relay Duration. Press REGEN to
return to previous step.
STEP 18 S – Use up and down arrows to set duration of relay activation in minutes.
Range = 0:01 (1 second) - 500:00 (500 minutes). Press NEXT to go to Step 26S.
Press REGEN to return to previous step.
STEP 19 S – REGEN gallons chosen to activate relay. Relay activates after set
number of gallons have been used in service or during regeneration and then de-
activates after set period of time or after flow stops, whichever comes first. Press
NEXT to go to Step 20S.