Download Print this page

Service - Honeywell VR8345M Manual

Universal electronic ignition gas control
Hide thumbs Also See for VR8345M:

Advertisement

WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE,
SEVERE INJURY OR DEATH
Do not disassemble the gas control; it contains no
replaceable components. Attempted disassembly
or repair can damage the gas control.
CAUTION
Do not apply a jumper across or short the valve coil
terminals. Doing so can burn out the heat anticipator
in the thermostat or damage the ignition module.
IF MAIN BURNER WILL NOT COME ON WITH
CALL FOR HEAT
1. Make sure the gas control knob is in the ON position.
2. Adjust the thermostat several degrees above room
temperature.
INSTRUCTIONS TO THE HOMEOWNER (FOR
YOUR SAFETY, READ BEFORE OPERATING)
WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE,
SEVERE INJURY, OR DEATH
Follow these warnings exactly:
1. Pilot/main burner flame is lit automatically. Do
not light the pilot/main burner flame manually.
2. Before lighting appliance, smell around the ap-
pliance for gas. Be sure to smell next to the floor
because LP gas is heavier than air.
3. IF YOU SMELL GAS:
• Turn off the gas supply at the appliance
service valve. On LP gas systems, turn off
gas supply at the gas tank.
• Do not light any appliances in the house.
• Do not touch electrical switches or use phone.
• Leave the building and use a neighbor's
phone to call your gas supplier.
• If you cannot reach your gas supplier, call
the fire department.
4. Do not force the gas control knob. Use only your
hand to push down or turn the gas control knob.
Never use any tools. If the gas control knob will
not operate by hand, call a qualified service
technician to replace the gas control. Force or
attempted repair can result in a fire or explosion.
5. Call a qualified service technician to replace the
gas control if it has been flooded with water.
6. Replace the gas control in the event of any
physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.
3. Using an ac voltmeter, check for voltage at the gas
control.
• Intermittent Pilot Igntion—If pilot lights, measure
voltage across MV/PV and MV. If pilot does not light,
measure across MV/PV and PV before safety lockout
occurs.
• Hot Surface or Direct Spark Ignition—Measure volt-
age across MV terminals at gas control.
4. If voltage is not present, check control circuit for pro-
per operation.
5. If proper control circuit voltage is present, replace gas
control.
IMPORTANT: Follow the operating instructions provided
by the manufacturer of your heating appliance. The
information below will be helpful in a typical gas
control application, but the specific controls used and
the procedures outlined by the manufacturer or your
appliance may differ and require special instructions.
TO TURN ON THE APPLICANCE
Stop: Read the Warnings on page 11.
The pilot/main burner flame is lit automatically. Do not
attempt to manually light the pilot. If the appliance does not
turn on when the thermostat is set several degrees above
room temperature, follow these instructions:
1. Set the thermostat to its lowest setting to reset the
safety control.
2. Disconnect all electric power to the appliance.
3. Remove the gas control access panel.
4. Push in the gas control knob slightly and turn clock-
wise
to OFF.
5. Wait five minutes to clear out any unburned gas. If you
then smell gas, STOP! Follow step 3 of the Warning in the
Instructions To The Homeowner section. If you do not smell
gas, continue with the next step.
6. Turn the gas control knob counterclockwise
to ON.
7. Replace the gas control access panel.
8. Reconnect all electric power to the appliance.
9. Set the thermostat to the desired setting.
10. If the appliance does not turn on, set the gas control
knob to OFF and contact a qualified service technician for
assistance.
TURNING OFF THE APPLIANCE
VACATION SHUTDOWN—Set the thermostat to the de-
sired room temperature while you are away.
COMPLETE SHUTDOWN—Push in the gas control knob
slightly and turn clockwise
Appliance will completely shut off. Follow the In-
structions to the Homeowner above to resume normal
operation.
17
VR8345M

SERVICE

Service
to OFF. Do not force.
68-0160

Hide quick links: