Electrical Connection; Manufacturer - Zanussi ZBG331XP Instruction Booklet

Gas oven
Table of Contents

Advertisement

Electrical Connection

The oven is designed to be connected to 230 V (50Hz)
electricity supply.
The oven has an easily accessible terminal block which
is marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given below.
Min. size Cable/flex
1.5 mm
2
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains), with
a minimum gap of 3mm between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The switch must not break the yellow-green earth wire
at any point. The earth wire should be 2 cm longer than
the phase and neutral wires.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a temperature
of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse
and the domestic installation can support the load and
that the power supply is properly earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
14
Cable / flex type
Fuse
H05 RR-F
13 A
Neutral wire
Earth wire
(yellow-green)
at least 2 cm longer
Phase wire