Updating A Patch Script That Will Be Run On Systems Modules - IBM XIV User Manual

Storage system
Hide thumbs Also See for XIV:
Table of Contents

Advertisement

Updating a Patch Script that will be Run on Systems Modules

Updates a patch script that will be run on system's module(s).
Parameters:
Updates a patch script that will be run on system's module(s).
Example:
Access Control:
patch_script_update name=Name [ module_list=ModuleList ]
[ module_type=<data|interface|specific|all> ] [ version=Version ]
[ persistence=<yes|no> ] [ run_option=<Always|Once> ]
[ parameters=(p1,p2,p3....p10) ] [ enabled=<yes|no> ]
[ description=Description ]
Name
Type
N/A
module_
list
Enumeration
module_
type
name
String
Boolean
persistenc
e
run_option
Enumeration
parameters
String
enabled
Boolean
version
String
String
descriptio
n
xcli -u -c XIV1 patch_script_update module_type=all name=upgrade_script
User Category
Storage administrator
Storage integration administrator
Description
Mandatory
Module numbers
N
that it should
execute on.
Format:
module_no(1-
15(format:/4/5/6/
).
Module types
N
(data/interface)
that it should
execute on.
(Default of all). If
using specific,
module parameter
should be specified
as well.
Script Name.
Y
Script persistence.
N
Script run option:
N
Always, Once.
Patch script
N
parameters
devided by " ".
User
N
enabling/disabling
the patch script.
Script version.
N
Script description.
N
Permission
Disallowed
Disallowed
Chapter 9. System Management
Default
None
all
N/A
yes
Once
None
no
None
None
147

Hide quick links:

Advertisement

Table of Contents
loading