Electrical Connection

The oven is designed to be connected to 230
V (50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L
-
Letter N
-
or E
-
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the
electrical supply must comply to the
specifications given below.
Connection
Min. size
via
Cable/flex type
13 A socket
2.5 mm
outlet
13 A spur box
Oven
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/
Cable / flex type
flex
2.5 mm
H07 RN-F, H05 RN-F, 15 A
2
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
Live terminal
Neutral terminal
Earth terminal
Cable / flex Fuse
2
3 core
13 A min.
butyl
insulated
2
PVC/PVC
15 A min.
twin and
20 A max.
earth
Fuse
It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of
3mm between the switch contacts and of a
type suitable for the required load in
compliance with the current rules.
The switch must not break the yellow and
green earth cable at any point.
the yellow and green earth cable should be
2-3 cm longer than the other cables.
Important
After installation and connecting, the cable
must be placed so that it cannot at any point
reach a temperature of more than 60°C
above the ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation
can support the load and that the power
supply is properly earthed.
The
manufacturer
responsibility should these safety
measures not be carried out.