FOR MODELS WITH A WATER SOFTENER
AN 'APPROVED' DOUBLE CHECK VALVE OR SOME OTHER NO LESS EFFECTIVE DEVICE PROVIDING
BACKFLOW PREVENTION PROTECTION TO AT LEAST FLUID CATEGORY TWO SHALL BE FITTED AT THE
POINT OF CONNECTION BETWEEN THE WATER SUPPLY AND THE FITTING OR APPLIANCE.
FOR MODELS WITHOUT A WATER SOFTENER
AN 'APPROVED' SINGLE CHECK VALVE OR SOME OTHER NO LESS EFFECTIVE DEVICE PROVIDING
BACKFLOW PREVENTION PROTECTION TO AT LEAST FLUID CATEGORY TWO SHALL BE FITTED AT THE
POINT OF CONNECTION BETWEEN THE WATER SUPPLY AND THE FITTING OR APPLIANCE.
The dynamic water supply pressure must be between 1 and 6 bar; if it is higher a pressure reducer
must be installed.
It is essential to fit a main stop tap on the water intake deliver pipeline; the tap must be accessible
after installation of the appliance, so do not install it behind the warewasher. The stated cycle
duration applies to appliances supplied with hot water >50°C<60°C If the warewasher is supplied
with cold water, the cycle duration might increase depending on the intake water temperature.
The warewasher is fitted with a drain pump and can operate with drain connections on the floor or
wall.
Refer to the connection diagram for the maximum permitted height of wall drains – (see TECHNICAL
DATA)
Caution: make sure that the intake and drain hoses are not bent, constricted or crushed
after installation.
When installing the drain hose to a siphon with valve, the maximum height of the drain outlet is
reduced to 600 mm.
CW/CWH – 511 MDA