FOR MODELS WITH A WATER SOFTENER 
AN  'APPROVED'  DOUBLE  CHECK  VALVE  OR  SOME  OTHER  NO  LESS  EFFECTIVE  DEVICE  PROVIDING 
BACKFLOW PREVENTION PROTECTION TO AT LEAST FLUID CATEGORY TWO SHALL BE FITTED AT THE 
POINT OF CONNECTION BETWEEN THE WATER SUPPLY AND THE FITTING OR APPLIANCE.  
 
FOR MODELS WITHOUT A WATER SOFTENER 
AN  'APPROVED'  SINGLE  CHECK  VALVE  OR  SOME  OTHER  NO  LESS  EFFECTIVE  DEVICE  PROVIDING 
BACKFLOW PREVENTION PROTECTION TO AT LEAST FLUID CATEGORY TWO SHALL BE FITTED AT THE 
POINT OF CONNECTION BETWEEN THE WATER SUPPLY AND THE FITTING OR APPLIANCE. 
 
The dynamic water supply pressure must be between 1 and 6 bar; if it is higher a pressure reducer 
must be installed. 
It is essential to fit a main stop tap on the water intake deliver pipeline; the tap must be accessible 
after installation of the appliance, so do not install it behind the warewasher. The stated cycle 
duration applies to appliances supplied with hot water >50°C<60°C If the warewasher is supplied 
with cold water, the cycle duration might increase depending on the intake water temperature. 
 
The warewasher is fitted with a drain pump and can operate with drain connections on the floor or 
wall.  
Refer to the connection diagram for the maximum permitted height of wall drains – (see TECHNICAL 
DATA) 
 
Caution: make sure that the intake and drain hoses are not bent, constricted or crushed 
 
after installation. 
 
 
When  installing  the  drain  hose  to  a  siphon  with  valve,  the  maximum  height  of  the  drain  outlet  is 
reduced to 600 mm. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 