The Chimney - Harman TLC 2000 Installation And Operating Manual

Coal/wood stove
Table of Contents

Advertisement

Hole with a minimum
clearance of 18" (450 mm)
between connector and
wall.
AN APPROVED CANADIAN
WALL PASS-THROUGH
The NFPA (National Fire Protection Association)
permits four methods for passing through a combustible
wall. A commonly used method to pass through a wall
directly to a masonry chimney is to clear a minimum
12"(300 mm) around the entire chimney connector, and
fill it with brick masonry which is at least 3.5"(90 mm)
thick. A fireclay liner, minimum 3/8" (9 mm) wall thick-
ness must run through the brick wall to the chimney liner
(but not beyond the inner surface of the liner). It must be
cemented in place with refractory cement. This method
is illustrated. For details on the other three options,
refer to the most recent edition of the NFPA 211 code.

The Chimney

The TLC 2000 must be installed into a chimney ap-
proved for use with solid-fuel appliances. In the U.S.,
the TLC 2000 must be connected to (1) a prefabricated
chimney complying with the requirements for Type HT
chimneys in the Standard for Chimneys, Factory-Built,
Residential Type and Building Heating Appliances, UL
103, or (2) a code-approved masonry chimney with
a flue liner. In Canada, the TLC 2000 is listed for use
with prefabricated chimneys tested and listed to the
high temperature (650 degrees C) chimney standard,
ULC S-629, or with a code approved masonry chimney.
The minimum recommended height for any chimney
is 16 ft (4.8 m) above flue collar height. A round flue
(either masonry or approved prefabricated), of either 6"
(150 mm), 7" (180 mm) or 8" (200 mm) may be used.
For square or rectangular masonry chimneys, nominal
sizes of 8" x 8"or 8"x 12" (200 mm x 200 mm, 200 mm
x 300 mm) may be used.
Chimney System
Non-combustible cover,
one side only. If two
covers are used, each
must be mounted on
non-combustible spacers
at least 7/8" (21mm) away
from the wall.
1" (25mm)
Clearance
Minimum 12" (300mm)
to Combustibles
18
Closest
Combustible
Minimum 2" (50mm)
Material
Clearance to Brick
Liner
Masonry Chimney Built to
NFPA 211 Specifications.
AN APPROVED U.S.
WALL PASS-THROUGH
More Than 10 ft. (3m)
10 ft. (3m)
2 ft. (0.6m) min.
Ridge
Chimney
The 3-foot, 2-foot, 10 foot rule
Codes require that solid-fuel chimneys extend 3 ft
(0.9 m) above the point at which they exit from the roof,
provided that no part of any structure is within the top
of the chimney, then the chimney must extend 2 ft (6
m) above the highest point with the 10 ft (3 m) radius
top height. If there is not ten feet of clearance from the
top of the chimney, then the chimney must extend 2 ft
(6m) above the highest point with the 10 ft (3m) radius.
Minimum 12"
(300mm) to Brick
Fire Clay
Thimble
Chimney
Connector
Height Necessary
Above Any Roof
Surface Within
10ft. (3m)
3ft. (0.9m)
minimum
above
exit
point

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF