4. Secure the L1 (black) and L2 (red) power leads to the outside terminal studs
(brass colored) with nuts.
5. Secure the bare copper ground lead to the range chassis using the ground
screw previously used for the ground strap. Be sure that neutral and ground ter-
minals do not touch.
6. Tighten all connections securely.
Bend Ground Strap Up
L1 Black
Figure 13: Ground Strap
L2 Red
Ground Wire
Figure 14: Secure Neutral Wire