If you are using a DA-38 or DA-98, your master word clock should be set to TDIF1 A. This makes your
Multitrack machine the word clock master. The DA-38 and DA-98 can both transmit word clock
information through the TDIF1 line, and the TM-D1000 will follow that. NOTE: The TDIF cable must be
connected from the DA-38 or DA-98 to the TM-D1000 before setting the Master Word Clock. Otherwise,
the TM-D1000 display will read "Error! No Signal TDIF-1 A". This means there is no word clock
information at the TDIF port. The TM-D1000 then resets the Master Word clock to the internal clock.
If you are using a DA-88, your master word clock should be set to Word Sync In [44.1k] or Word Sync
In [48k] depending on what sample rate you are using. If you formatted your tape at 44.1kHz, then use
Word Sync In [44.1k]. If you formatted your tape at 48kHz, then use Word Sync In [48k]. If you don't
know which sample rate you selected for your machine, there are two indicator lights on the DA-88 just
to the right of the "tape eject" button labelled 44.1k and 48k. NOTE: The BNC to RCA cable must be
connected from the DA-88 to the TM-D1000 before setting the master word clock. Otherwise, the TM-
D1000 display will read "Error! Fs Clock Error>Internal". This means there is no word clock information
at the Word Sync In port. The TM-D1000 then resets the master word clock to the internal clock.
If you are using an ADAT or another lightpipe unit with an IF-TAD, your master word clock should
be set to Word Sync In [44.1k] or Word Sync In [48k] depending on what sample rate you are using. If
you formatted your tape at 44.1kHz, then use Word Sync In [44.1k]. If you formatted your tape at 48kHz,
then use Word Sync In [48k]. NOTE: The BNC to RCA cable must be connected from the IF-TAD to the
TM-D1000 before setting the master word clock. Otherwise, the TM-D1000 display will read "Error! Fs
Clock Error>Internal". This means there is no word clock information at the Word Sync In port. The TM-
D1000 then resets the master word clock to the internal clock.
To set the master clock on the TM-D1000:
1) Press SHIFT and PARAM SEL simultaneously.
1/99
Section III, Continued

Master Word Clock Set-up

TASCAM
TM-D1000
Section III, page 3
2) Rotate the DATA ENTRY dial to SYSTEM.
Press ENTER.
Option
System
3) Rotate the DATA ENTRY dial to Master Clock Select.
Press ENTER.
System
Master Clock Select
4) Rotate the DATA ENTRY dial to the appropriate source.
Press ENTER.
Master Clock Select
?
?
TDIF-1 A?