Mount the inner flange onto the spindle. Fit the cut-off
wheel on over the inner flange.
Mount the outer flange on the wheel and screw the lock
nut with its protrusion facing downward (facing toward
the wheel).
To tighten the lock nut, press the shaft lock firmly so that
the spindle cannot revolve, then use the lock nut wrench
and securely tighten clockwise.
To remove the wheel, follow the installation procedure in
reverse.

OPERATION

WARNING:
It should never be necessary to force the tool. The
weight of the tool applies adequate pressure.
Forcing and excessive pressure could cause
dangerous wheel breakage.
ALWAYS replace wheel if tool is dropped while
grinding.
NEVER bang or hit grinding disc or wheel onto
work.
Avoid bouncing and snagging the wheel, especially
when working corners, sharp edges etc. This can
cause loss of control and kickback.
NEVER use tool with wood cutting blades and
other sawblades. Such blades when used on a
grinder frequently kick and cause loss of control
leading to personal injury.
CAUTION:
Never switch on the tool when it is in contact with
the workpiece, it may cause an injury to operator.
Always wear safety goggles or a face shield during
operation.
After operation, always switch off the tool and wait
until the wheel has come to a complete stop before
putting the tool down.
Grinding and sanding operation
ALWAYS hold the tool firmly with one hand on rear
handle and the other on the side handle. Turn the tool on
and then apply the wheel or disc to the workpiece.
In general, keep the edge of the wheel or disc at an
angle of about 15 degrees to the workpiece surface.
During the break-in period with a new wheel, do not work
the grinder in the B direction or it will cut into the
workpiece. Once the edge of the wheel has been
rounded off by use, the wheel may be worked in both A
and B direction.
A
B
005011

MAINTENANCE

CAUTION:
Always be sure that the tool is switched off and
unplugged before attempting to perform inspection
or maintenance.
1
005012
The tool and its air vents have to be kept clean.
Regularly clean the tool's air vents or whenever the
vents start to become obstructed.

Replacing carbon brushes

1
001146
When the resin insulating tip inside the carbon brush is
exposed to contact the commutator, it will automatically
shut off the motor. When this occurs, both carbon
brushes should be replaced. Keep the carbon brushes
clean and free to slip in the holders. Both carbon
brushes should be replaced at the same time. Use only
identical carbon brushes.
Use a screwdriver to remove the brush holder caps.
Take out the worn carbon brushes, insert the new ones
and secure the brush holder caps.
7
15
1. Exhaust vent
2. Inhalation vent
2
1. Commutator
2. Insulating tip
2
3. Carbon brush
3