Planning Installation - Empire Comfort Systems OP32FB2MF-2 Installation Instructions And Owner's Manual

Outdoor ventless firebox
Table of Contents

Advertisement

In planning the installation for the firebox, it is necessary to determine
where the unit is to be installed and whether optional accessories
are desired. Gas supply piping should also be planned at this time.
The firebox can be mounted on any of these surfaces:
1. a flat non-combustible surface.
2. A raised platform non-combustible material.
3. Four corners of the firebox so contact is made on all four
perimeter edges on the bottom of the unit.
(Example: Four concrete masonry blocks.)
If the firebox is installed directly on carpeting, tile or other combustible
material other than wood flooring, it should be installed on a metal
or wood panel extending the full width and depth of the unit.
At this point, you should have decided what components to include
in your installation, and where the firebox is to be located. If this
has not been done, stop and consult your dealer for assistance
with this planning.
This firebox is intended for installation on an outdoor patio or
in your yard. This firebox shall be used only outdoors in a well
ventilated space and shall NOT be used in a building, garage, or
other enclosed area.
It is recommended that this firebox be installed in a "sheltered" area.
direct wind will cause an erratic flame and possible pilot or main
burner outage. This erratic flame could also lead to excessive black
soot. These issues are nuisance issues rather than a safety issues.
Typical installation may include covered patio, screened porch,
gazebo or an outside wall of a house.
Minimum porch area – 96 square feet
Minimum ceiling height – 92 inches
Outdoor Firebox Enclosure Requirements
Do not install appliance until all necessary provisions are made
for combustion and ventilation air. Consult the written instructions
provided with the appliance for information concerning combustion
and ventilation air. In the absence of instructions, refer to the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion
and Ventilation, or applicable local codes.
This fireplace has not been tested nor approved to have a televi-
sion or other electrical appliance installed above it.
32273-0-0713

PLANNING INSTALLATION

WARNING`
Installation must conform with one of the following conditions:
With walls on all sides, but with no overhead cover;
Within a partial enclosure which includes an overhead cover
and no more than two side walls. These side walls may be
parallel, as in a breezeway or at right angles to each side; or
Within a partial enclosure which includes an overhead cover
and three sidewalls, as long as 30% or more of the horizontal
periphery of the enclosures is permanently open.
The maximum bTU's for this firebox is 50,000. Verify that any
appliance and/or accessory are rated for use up to 50,000 Btu
before installing it into this firebox. Follow any special installation
instructions that came with the appliance or accessory (i.e.
clearances, combustion and ventilation air, and enclosure
information).
Improper installation, adjustment, alteration, service or mainte-
nance can cause property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Clearances
The front of the firebox may have 0" clearance as far back as 1/2"
where studs are to be placed.
WARNING
Figure 4
Figure 5
Page 9