8 Troubleshooting
Fault
Pressure drop
Pressure fl uctuations
The motor does not start when
the cleaner is switched on
Cause
> Air in the system
> High-pressure nozzle blok-
ked/worn
> Pressure control on the
spray pipe is not set correct-
ly.
> Pump draws in air (only
possible in suction mode)
> Lack of water
> Water inlet hose is too long
or its cross-section too small
> Lack of water caused by
blocked water fi lter
> Lack of water because max.
permissible suction height
has not been heeded
> The plug is not inserted pro-
perly, i.e. there is no current
> The mains fuse is switched
off
Remedy
Vent the system by opera-
ting the spray gun several
times at short intervals. If
necessary, operate the clea-
ner for a short time without
the high-pressure hose
connected
Clean/replace the high-pres-
sure nozzle
Set the required working
pressure
Check that the suction set is
air-tight
Open the tap
Use specifi ed water inlet
hose
Clean the water fi lter in the
water connection (never
work without water fi lter)
See instructions
Check the plug, lead and
switch and if necessary have
them replaced by a trained
electrician
Switch on the mains fuse
39