I N S TA L L AT I O N
I N S T R U C T I O N S
G A S S U P P LY
R E Q U I R E M E N T S
EXPLOSION HAZARD —
Use a new CSA approved gas supply line
and install a gas shut-off valve.
Securely tighten all gas connections.
For LP gas, have a qualified technician
make sure the gas pressure does not
exceed 14" (34.9 mb) WC (water column).
Failure to do so can result in explosion,
fire or death.
IMPORTANT NOTE: The dual fuel range must
be connected to a regulated gas supply.
IMPORTANT NOTE: This installation must
conform with local codes and ordinances. In
the absence of local codes, installations must
conform with American National Standard,
National Fuel Gas Code ANSI Z223.1 – latest
edition or CANI – B149.1 or 2.
The range is equipped for use with natural or
LP gas. It is design certified by the Canadian
Standards Association (CSA) for natural or LP
gases. The rating plate, located at the far right
of the bottom of the control panel assembly
just above the oven door, has information on
the type of gas that should be used. If this
information does not agree with the type of
gas available, check with the local gas supplier.
SHUT-OFF VALVE
Open Position
Gas Supply
To Appliance
Line
Shut-off valve
Dimensions in parentheses are in
millimeters unless otherwise specified.
Provide a gas supply line of
the range location. A smaller size pipe on long
runs may result in insufficient gas supply. Pipe
joint compounds, suitable for use with LP gas
should be used. For LP gas, piping or tubing
1
size can be
/
" minimum. LP gas suppliers
2
usually determine the size and materials used
on the system.
If local codes permit, a new CSA design
1
certified, 3' (.9 m) long,
/
" or
2
metal appliance connector is recommended for
connecting this range to the gas supply line.
Do not kink or damage the flexible connector
when moving the range. The pipe coming out
the bottom of the unit has
You will need to determine the fittings
required, depending on the size of your gas
supply line, flexible metal connector and
shut-off valve.
If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the range. All
strains must be removed from the supply and
gas lines so the range will be level and in line.
IMPORTANT NOTE: The supply line must
be equipped with an approved external gas
shut-off valve located near the range in an
accessible location. Do not block access to the
shut-off valve. Refer to the illustration below.
3
/
" rigid pipe to
4
I M P O R TA N T
N O T E
This installation
must conform with
3
/
" ID flexible
4
local codes and
ordinances. In the
absence of local
codes, installations
must conform with
1
/
" male threads.
the American
2
National Standard,
National Fuel Gas
Code.
13