Time; Programming For Departments; Unit Price - Sharp ER-A450 Instruction Manual

Electronic cash register
Hide thumbs Also See for ER-A450:
Table of Contents

Advertisement

Time

PGM 2
Set the time using the 24-hour format. For example, when the time is set to 2:30 AM, enter 230; and when it is
set to 2:30 PM, enter 1430. Once you set the time, the internal clock unit will continue to run as long as the
built-in battery is alive and update the date (day, month, year) properly.
Procedure
X X X X
Time (max. four digits)
Example
Setting the time as 2:30 PM (14:30)

Programming for departments

2
Your machine is equipped with 20 standard departments and up to 50 optional departments.
Your machine allows you to perform the following programming for each department:

Unit price

Procedure
Department
key
* Unit price: max. six digits (9999.99)
Example
Programming the unit price 10.00 for department 1
1.
Press the department 1 key.
• The current unit price will be displayed.
2.
Enter the unit price "1000."
3.
:
Press the
key to program this setting.
4.
;
Press the
key to finalize the programming
and generate a programming report.
16
=
Key operation
1430
PGM 1
PGM 2
To keep the current setting
*
Unit price
To program for the following dept.
To program for another dept.
=
;
:
1
1000
:
;
Print