To Start The Compressor:
TANK dRAIN VALVE
1.
Check to make sure the Air Tank's Drain Valve (52), located on the bottom Air Tank
(51), is fully closed.
2.
Turn the Air Outlet Valve (68) to its closed position.
3.
Connect an air hose (not included) to the previously installed Quick Connector.
Then, connect the other end of the air hose to the pneumatic tool (not included).
4.
Plug the Power Cord (55) into the nearest 120 volt, grounded, electrical outlet.
5.
Pull
up on the Pressure Switch (64) to its "START" position to turn on the unit.
6.
When the Tank Pressure Gauge (63) reaches at least
Valve to its open position to allow air to the pneumatic tool.
7.
Once the air pressure reaches the pneumatic tool, observe the Tool Pressure
Gauge (66). Adjust the Regulator (67) to feed the proper PSI to the tool. To do so,
turn the Regulator clockwise to increase the PSI. Turn the Regulator counterclock-
wise to decrease the PSI.
Note: When the maximum air pressure, 115 PSI, is reached as indicated by the Tank
Pressure Gauge (63), the motor will stop. The Compressor will automatically re-
start when the air pressure drops below 85 PSI.
IMPORTANT: To decompress the air pressure in the Air Tanks (51), push down on the
Pressure Switch (64) to its "STOP" position. Then, pull out on the Safety Release
Valve to immediately release air pressure from the Air Tanks.
SKU 95498

OPERATING INSTRuCTIONS

AIR HOSE
(NOT INCLudEd)
(52)
For technical questions, please call 1-800-444-3353.
AIR
OuTLET
VALVE
(68)
TOOL
PRESSuRE
GAuGE
(66)
FIGuRE F
REGuLATOR
(67)
PRESSuRE SWITCH
85 PSI, turn the Air Outlet
(64)
TANK
PRESSuRE
GAuGE
(63)
SAFETY
RELEASE
VALVE
(62)