READ BEFORE INSTALLING

Clearance:

When installing ovens against combustible surfaces (rear or side walls) 0" clearance is required. When
installing ovens against non-combustible surfaces (rear or side walls) 0" clearance is required.

Leveling:

A carpenter's spirit level should be placed on the oven's center baking rack and the unit leveled both
front-to-back and side-to-side. If it is not level, cakes, casseroles, and any other liquid or semi-liquid
batter will not bake evenly, burner combustion may be erratic, and the unit will not function efficiently.
If the floor is relatively smooth and level, the unit may be further leveled with adjustment in the foot of
the leg. Units with casters must be leveled with shims. A unit will probably not return to the same
position after being moved, requiring re-leveling after each and every move.

Rating Plate:

The rating plate is located in front of the oven below the oven section. Information on this plate includes
the model number, serial number, power input, ampere draw and clearances from combustible and
non-combustible surfaces. Metal tag with serial number is located on the top right corner of the unit.
UNIT MUST BE CONNECTED ONLY TO THE POWER INPUT IDENTIFIED ON THE RATING PLATE!

Electrical Connection:

Convection ovens have a single point power connection at the terminal block. Check for single phase or
three phase connection and connect accordingly. The electrical service in the building must be equipped
with a properly grounded receptacle, in accordance with local codes, or in the absence of local codes,
with the national electrical code, ANSI/NFPA 70-latest edition, in Canada, conform with Canadian
electrical codes CSA- C22.1. 208V or 240V single and three phase wires should be properly connected as
shown in the wiring diagram. 480V connection is ONLY with three phase and a step down transformer.
Do not cut or remove the grounding wire. Wiring diagram is located on the backside of the appliance.
Disconnect power supply before cleaning or servicing.
NOTE: This appliance is not capable of being operated in the event of power failure. No attempt should
be made to operate this appliance during power failure.
IMPROPER CONNECTION TO POWER SUPPLY OTHER THAN WHAT IS DESIGNATED ON DATE
PLATE WILL VOID WARRANTY.