Hard Disk Maintenance

When a power failure occurs while in the Recording mode or
Alarm Record Standby mode, or when a failure occurs in the
recorded data on the hard disk, recording/playback may not
function properly. To repair the hard disk, two types of scan disk
functions are available on the VR-509:

AUTO SCAN DISK

Scans the hard disk automatically when the power is switched
on.
1. Press the [MENU] button.
• Opens the menus in accordance with the instructions
provided in Changing MENU Settings (page 17) in the
sequence of [MENU] → [OPERATION MENU] →
[MAINTENANCE].
MAINTENANCE
AUTO SCAN DISK

MANUAL SCAN DISK

ALARM LIST CLEAR
DEFRAG DATABASE..
FORMAT..
MIRRORING..
PASSCODE SET..
MAINTENANCE/LOG..
AREA SELECT..
2. Select [AUTO SCAN DISK] with [ / ].
3. Select [ON] with [–/+].
4. Press the [SET] button.
• A confirmation screen will be displayed.
5. Select [SAVE] with [ / ], and then press the [SET]
button.
50
2.
3.
OFF
EXEC
EXEC
MANUAL SCAN DISK
Performs manual scanning of the hard disk. Perform Manual
Scan Disk regularly when the [AUTO SCAN DISK] item in the
menu is set to "OFF" or when the power to the equipment
remains on for extensive periods of time. (About once a month)
1. Press the [MENU] button.
• Opens the menus in accordance with the instructions
provided in Changing MENU Settings (page 17) in the
sequence of [MENU] → [OPERATION MENU] →
[MAINTENANCE].
MAINTENANCE
AUTO SCAN DISK
MANUAL SCAN DISK
ALARM LIST CLEAR
DEFRAG DATABASE..
FORMAT..
MIRRORING..
PASSCODE SET..
MAINTENANCE/LOG..
AREA SELECT..
2. Select [MANUAL SCAN DISK] with [ / ], and then
press the [SET] button.
• The SCAN DISK function will be executed.
Press the [CANCEL] button to abort the scandisk
process.
This has no effect if the scandisk process is stopped in
the middle of progress.
There are cases where the time required for ending the
process is extended if the size of the recorded event is
large or there are a large number of events (several
hours).
Recording, playback and search functions cannot be
used when the scandisk procedure is running.
CAUTION
The manual scandisk process cannot be executed when in
the following operation modes:
During recording.
During the playback of recorded images.
When the timer is ON.
During DVD export.
When a malfunction occurs with the hard disk.