Electrical Requirements - Maytag MEDX600XW0 Installation Instructions Manual

27" wide models
Hide thumbs Also See for MEDX600XW0:
Table of Contents

Advertisement

[] Ifyouareusing power supply cord, a grounded electrical
outlet l ocated w ithin 2 ft.(610 mm) o feither s ide ofdryer.
See "Electrical Requirements."
[] Asturdy floor t osupport thetotal w eight (dryer andload)
of200Ibs. ( 90.7 kg). T he combined weight ofacompanion
appliance should also beconsidered.
[] Level floorwithmaximum s lope of1"(25mm) u nder e ntire
dryer. (Ifslope isgreater than 1"[25mm], i nstall Extended
Dryer Feet K it, P art N umber 279810.) Ifnotlevel, clothes
may nottumble p roperly and automatic sensor cycles m ay
notoperate c orrectly.
Donotoperate yourdryer a ttemperatures
below 45°F (7°C). At
lower temperatures,
thedryer m ight n otshut o ffattheendofan
automatic cycle. Drying t imes canbeextended.
The dryer m ust n otbeinstalled orstored inanarea where itwill
beexposed towater a nd/or weather.
Check c ode requirements.
Some codes l imit, o rdonotpermit,
installation ofthedryer i ngarages, closets, mobile h omes, or
sleeping quarters. Contact yourlocal b uilding i nspector.
Installation
clearances:
The location must be large enough to allow the dryer door
to open fully.
Dryer Dimensions
13sA ,,
mm)
A
A. Large opening side-swing
door
B. Wide opening hamper door
*Most installations require a minimum 51/2"(140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
spacing for recessed
area or
closet installation
The dimensions shown following are for the minimum spacing
allowed.
[]
Additional
spacing should be considered for ease of
installation and servicing.
[]
Additional
clearances might be required for wall, door, and
floor moldings.
[]
Additional
spacing of 1" (25 mm) on all sides of the dryer is
recommended
to reduce noise transfer.
[]
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
[]
Companion appliance spacing should also be considered.
Minimum Required
Spacing
f_P_
1"_1 _ 27"_ _ 1,,
(_mr,)
_
1411max,* _ -
--
_ m
48 in?
__
_
(310cm) 2
_
_
24i_*
÷11"I< 29,/," _15,/_"*_
(686turn}(25ram) (25mm} 1748mm}
(148mm}
A
B
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional
spacing
recommended
311,
(76 ram)
-T
3 I1.
(76 ram)
T
Mobile
home
= Additional
installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
[]
[]
Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such
as a nearby window) should be at least twice as large
as the dryer exhaust opening.
E(ectdca(
Requ
It is your
responsibility:
[]
To contact a qualified electrical installer.
[]
To be sure that the electrical connection is adequate and in
conformance
with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association,
One Batterymarch
Park,
Quincy, MA 02269.
[]
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified
on the serial/rating
plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended.
Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
[]
Do not use an extension cord.
[]
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.
4