DRYER VENTING REQUIREMENTS
Vent Hoods
4" (102 ram) Diameter Exhaust Hoods
Box Hood
Louvered Hood
Angled Hood
Vent System Length
Exhaust hood must be at least 12" (305 mm) from the ground
or
any object that may be in the path of the exhaust (such as flowers,
rocks, bushes,
or snow).
Maximum
Vent
Length/Vent
Connection
Maximum
length of vent system depends
upon the type of vent
used, number of elbows, and type of exhaust hood.
3. Tighten
hose clamp with Phillips screwdriver.
Vent System Chart (Rigid Metal Vent)
No. of
Box and
Angled
90 ° Turns
Louvered Hood
Hood
0
130 ft. (39.6 m)
129 ft. (39.3 m)
1
125 ft. (38.1 m)
119 ft. (36.3 m)
2
115 ft. (35.1 m)
109 ft. (33.2 m)
3
106 ft. (32.3 m)
100 ft. (30.5 m)
4
98 ft. (29.9 m)
92 ft. (28.0 m)
For vent systems not covered
by the vent specification
chart,
see your parts distributor.
Provision
must be made for enough
air for combustion
and
ventilation.
(Check governing
codes and ordinances.)
See
"Recessed
Area and Closet
Installation
Instructions"
in the
"Location
Requirements"
sections.
A 4" (102 ram) outlet hood is preferred.
However,
a 21/2 '' (64 mm)
outlet exhaust
hood may be used. A 21/2 '' (64 mm) outlet creates
greater
back pressure
than other hood types. For permanent
installation,
a stationary
vent system
is required.
Connect Vent
1. If connecting
to existing vent, make sure the vent is clean.
2. Using a 4" (102 mm) clamp, connect
vent to exhaust
outlet
in dryer.
Vent Collar
NOTE: Do not remove vent collar.
4. Make sure the vent is secured
to exhaust
hood with
a 4" (102 ram) clamp.
5. Move dryer into final position.
Do not crush or kink vent.
Make sure dryer is level.
14