Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported when
the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and kinking
that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings, or
floors.
The total length of flexible metal vent should not exceed
73Aft. (2.4 m).
Elbows
45 ° elbows provide better airflow than 90 ° elbows.
Clamps
Good
Better
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or
other fastening devices that extend into the interior of the duct
and catch lint. Do not use duct tape.
Clamp
Exhaust
A and B: Recommended hood styles.
C: Acceptable hood style.
_
(1:4_m)
(102 ram)
A. Louvered hood style
B. Box hood style
C. Angled hood style
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks, or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork,
furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning
problems and health problems.
Plan Vent System
Choose your exhaust installation
type
Recommended
exhaust
installations
Typical installations vent the dryer from the rear of the dryer. Other
installations are possible.
B
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side, or
through the bottom. If you prefer, you may contact your local dealer
to have the dryer converted.
Fire Hazard
Cover unused exhaust
holes with the following
kit:
W10470674 (midnight
grey)
Contact
your local cleaner.
Failure to follow these instructions can result in death,
fire, electrical
shock,
or serious injury.