Maytag MEDE900VJ - Performance 7.5 cu. Ft. Steam Electric Dryer Installation Instructions Manual
Maytag MEDE900VJ - Performance 7.5 cu. Ft. Steam Electric Dryer Installation Instructions Manual

Maytag MEDE900VJ - Performance 7.5 cu. Ft. Steam Electric Dryer Installation Instructions Manual

Installation instructions
Hide thumbs Also See for MEDE900VJ - Performance 7.5 cu. Ft. Steam Electric Dryer:

Advertisement

ELECTRIC DRYER INSTALLATION INSTRUCTIONS
U.S.A. ONLY
Para una versi6n de estas instrucciones
en espa_ol, visite www.Whirlpool.com
TABLE OF CONTENTS
DRYER SAFETY ..............................................................................
1
................................................
2
Tools and Parts ............................................................................
2
Optional Equipment .....................................................................
3
Location Requirements ................................................................
3
ELECTRIC DRYER POWER HOOKUP ......................................... 5
Electrical Requirements ...............................................................
5
Electrical Connection ...................................................................
6
VENTING .......................................................................................
11
Venting Requirements ................................................................
11
Plan Vent System .......................................................................
12
Install Vent System .....................................................................
13
INSTALL LEVELING LEGS ...........................................................
13
CONNECT VENT ...........................................................................
14
(STEAM MODELS) ........................................................................
14
LEVEL DRYER ..............................................................................
15
COMPLETE INSTALLATION .......................................................
15
TROU BLESHOOTING ..................................................................
15
DRYER SAFETY
Your safety
and the safety
of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediatel_
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions
are not followed.
W10255468C
W10259190B - SP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEDE900VJ - Performance 7.5 cu. Ft. Steam Electric Dryer and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maytag MEDE900VJ - Performance 7.5 cu. Ft. Steam Electric Dryer

  • Page 1: Table Of Contents

    ELECTRIC DRYER INSTALLATION INSTRUCTIONS U.S.A. ONLY Para una versi6n de estas instrucciones en espa_ol, visite www.Whirlpool.com TABLE OF CONTENTS DRYER SAFETY ................INSTALL LEVELING LEGS ............INSTALLATION REQUIREMENTS ..........CONNECT VENT ................Tools and Parts ................CONNECT INLET HOSE Optional Equipment ..............(STEAM MODELS) ................
  • Page 2: Installation Requirements

    WARNING - "Risk of Fire" - Clothes dryer installation must be performed by a qualified installer. - Install the clothes dryer according to the manufacturer's instructions and local codes. - Do not install a clothes dryer with flexibJe plastic venting materials, if fle×ible metal (foiJ type) duct is instaJled, it must be of a specific...
  • Page 3: Optional Equipment

    Installation clearances Optional Equipment The location must be large enough to allow the dryer door to open fully. Refer to your Use and Care guide for information about the Dryer Dimensions accessories available for your dryer. Location Requirements Explosion Hazard Keep flammable materia(s and vapors, such as...
  • Page 4 Closet installation - Dryer only "i-_, 114' max. -,,e.---- (310 cm2) _ 48" 2* I 18"min,* (460 ram) (155 24"2" Cm2) -_4A*_,- B -_qO**_,-- Side View Side view Closet door with vents Steam Non-Steam Steam Non-Steam (Electric or Gas) (Electric or Gas) (Electric or Gas) (Electric or Gas) 1"...
  • Page 5: Electric Dryer Power Hookup

    Recommended installation spacing for cabinet 6"* (_52 mm) installation NOTE: Some models are not recommended for cabinet installation. • For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required. ( 976 1" 27"=}_ (25 mm) 686 mm (25mm)
  • Page 6: Electrical Connection

    To supply t herequired 3 or4wire, single p hase, 120/240 volt, If connecting by direct wire: 60Hz., A Conly electrical supply ( or 3 or4wire, 120/208 volt Power supply cable must match power supply (4-wire or 3-wire) electrical supply, ifspecified onthe serial/rating plate) ona and be: separate 30-amp c ircuit, fused onboth sides o ftheline.
  • Page 7 Remove the hold-down screw and terminal block cover. Style 2: Direct wire strain relief Fire Hazard Use 10 gauge solid copper wire. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire} to center A.
  • Page 8 Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a 4-wire connection: Power supply cord horizontal position. Tighten strain relief screw against the direct wire cable. IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.
  • Page 9 Connect ground wire (green or bare) of power supply cord to When connecting to the terminal block, place the hooked end of the external ground conductor screw. Tighten screw. wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
  • Page 10 5. Tighten strain r elief screw. 3-wire connection: Direct wire 6. Insert tabofterminal block c over into slot o fdryer rear p anel. Secure cover with hold-down screw. Use where local codes permit connecting cabinet-ground 7. You have completed your e lectrical connection. Now goto conductor to neutral wire.
  • Page 11: Venting

    4. Tighten strain relief screw. VENTING 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. You have completed your electrical connection. Now go to "Venting Requirements." Venting Requirements Optional 3-wire connection Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
  • Page 12: Plan Vent System

    Flexible metal vent • Do not use an exhaust hood with a magnetic latch. • Flexible metal vents are acceptable only if accessible for cleaning. improper venting can cause moisture and lint to collect • Flexible metal vent must be fully extended and supported when indoors, which may result in: the dryer is in its final location.
  • Page 13: Install Vent System

    • Plan the installationto use the fewest number of elbows and turns. _1 ¸¸ • When using elbows or making turns, allow as much room as possible. • Bend vent gradually to avoid kinking. • Use the fewest 90 ° turns possible. Determine vent length and elbows needed for best drying performance A.
  • Page 14: Connect Vent

    2. Firmly grasp the body of the dryer (not the console panel). Gently 4. Using pliers, tighten the couplings with an additional two-thirds lay the dryer on the cardboard. See illustration, turn. NOTE: Do not overtighten. Damage to the coupling can result. 5.
  • Page 15: Level Dryer

    Steam Models Only:. LEVEL DRYER 10. Be sure the water faucets are on. 11. Check for leaks around "Y" connector, faucet, and hoses. 12. If you live in a hard water area, use of a water softener is Check the levelness of the dryer. Check levelness first side to side, then front to back.
  • Page 16 Try the following: Is the exhaust vent or outside exhaust hood clogged with Check to see if a household fuse has blown or circuit breaker lint, restricting air movement? Run the dryer for 5-10 minutes. Hold your hand under the has tripped.

This manual is also suitable for:

Mede900vj 7.5

Table of Contents