3.
Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
B,
'
'
C
...... E
4=
5.
6.
7=
A. Extemal ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. 3/4" (19 mm) UL listed strain relief
D. Center terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
Connect the other wires to outer terminal block screws. Tighten
screws.
!
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
You have completed your electrical connection. Now go to
"Venting Requirements."
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection is required for mobile homes and
where local codes do not permit the use of 3-wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can
be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving bare
ground wire at 5" (127 mm). Cut 11/2"(38 mm) from 3 remaining
wires. Strip insulation back 1" (25 mm). Shape ends of wires into a
hook shape.
(127
When connecting to the terminal block, place the hooked end of the
wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
1=
2.
Remove center terminal block screw.
Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and place the hooked end
(hook facing right) of the neutral wire (white or center wire) of direct
wire cable under the center screw of the terminal block. Squeeze
hooked ends together. Tighten screw.
A
S .-•
D
E
3.
4.
A. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center terminal block screw.
B. Center terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain relief
Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
S
-
"
......... i ••
.......
E
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable
C. 3/4" (19 mm) UL listed strain relief
D. Center terminal block screw
E. Neutral ground wire
E Neutral wire (white or center wire)
Place the hooked ends of the other direct wire cable wires under
the outer terminal block screws (hooks facing right). Squeeze
hooked ends together. Tighten screws.