Maytag MEDE201YW Installation Instructions Manual
Maytag MEDE201YW Installation Instructions Manual

Maytag MEDE201YW Installation Instructions Manual

Performance series high-efficiency electric dryer
Hide thumbs Also See for MEDE201YW:

Advertisement

Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad
W10443041B
W10443042B-SP
Electric Dryer Installation Instructions

Table of Contents

DRYER SAFETY ......................................................................... 2
INSTALLATION REQUIREMENTS ............................................. 3
Tools and Parts ...................................................................... 3
Location Requirements ......................................................... 4
Electrical Requirements ........................................................ 6
Install Leveling Legs .............................................................. 7
Electrical Connection ............................................................ 8
Venting Requirements ......................................................... 14
Plan Vent System ................................................................. 15
Install Vent System .............................................................. 16
Connect Inlet Hoses ............................................................ 17
Connect Vent ........................................................................ 18
Level Dryer ........................................................................... 18
COMPLETE INSTALLATION CHECKLIST .............................. 19
DOOR REVERSAL .................................................................... 19
STACKING WASHER AND DRYER ......................................... 19
TROUBLESHOOTING .............................................................. 19
Date of purchase:
Date of installation:
________________________________________
Installer:
___________________________________
Model number:
___________________________________
Serial number:
INSTALLATION NOTES
_________________________________
_______________________________
producto, visite:
www.whirlpool.com
superior de la puerta.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEDE201YW and is the answer not in the manual?

Questions and answers

Summary of Contents for Maytag MEDE201YW

  • Page 1: Table Of Contents

    Electric Dryer Installation Instructions DRYER SAFETY ... 2 INSTALLATION REQUIREMENTS ... 3 COMPLETE INSTALLATION CHECKLIST ... 19 DOOR REVERSAL ... 19 STACKING WASHER AND DRYER ... 19 TROUBLESHOOTING ... 19 Date of purchase: Date of installation: Installer: Model number: Serial number: Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su Tenga listo su número de modelo completo.
  • Page 2: Dryer Safety

    DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
  • Page 3: Installation Requirements

    INSTALLATION REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before starting installation. Tools needed: Flat-blade screwdriver #2 Phillips screwdriver Wire stripper (direct wire Tin snips (new vent installations) installations) 1/4" nut driver Vent clamps (recommended) Adjustable wrench that Utility knife opens to 1"...
  • Page 4: Location Requirements

    LOCATION REQUIREMENTS You will need: A location allowing for proper exhaust installation. ■ See “Venting Requirements.” A separate 30 amp circuit. ■ If using power supply cord, a grounded electrical outlet ■ located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”...
  • Page 5 Door open view: (1238 mm) " (1197 mm) Back view: Electric 14" (358 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.” IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 45°...
  • Page 6: Electrical Requirements

    Closet Installation (stacked washer and dryer): 6" (152 mm) (1803 mm) " (140 mm) 1" 1" (25 mm) (25 mm) Custom under counter installation (dryer only): 1" (25 mm) NOTE: Some models not recommended for undercounter installation. Mobile home – Additional installation requirements: This dryer is suitable for mobile home installations.
  • Page 7: Install Leveling Legs

    If your outlet looks like this: Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30 R.
  • Page 8: Electrical Connection

    ELECTRICAL CONNECTION Power Supply Cord Electrical Connection Options Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to “Power Supply Cord Connection.” Power supply cord 3-wire receptacle (NEMA Type 10-30R): Go to “Power Supply Cord Connection.” 4-wire direct connection: Go to “Direct Wire Connection.”...
  • Page 9: Power Supply

    POWER SUPPLY CORD CONNECTION Power supply cord strain relief: Attach power supply cord strain relief Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place.
  • Page 10 Connect ground wire Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw. Connect remaining wires Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel.
  • Page 11: Direct Wire Connection

    DIRECT WIRE CONNECTION Direct wire strain relief Attach direct wire strain relief Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B).
  • Page 12: 3-Wire Direct Wire Connection

    Connect neutral ground wire and neutral wire Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw. Connect ground wire Connect ground wire (green or bare) (F) of direct wire cable to external ground conductor screw (A).
  • Page 13 Connect neutral wire Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw. Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right).
  • Page 14: Venting Requirements

    VENTING VENTING REQUIREMENTS WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building.
  • Page 15: Plan Vent System

    PLAN VENT SYSTEM Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.
  • Page 16: Install Vent System

    Determine vent path: Select route that will provide straightest and most direct ■ path outdoors. Plan installation to use fewest number of elbows and turns. ■ When using elbows or making turns, allow as much room ■ as possible. Bend vent gradually to avoid kinking. ■...
  • Page 17: Connect Inlet Hoses

    CONNECT INLET HOSES For non-steam models, skip to “Connect Vent” on page 18. The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses. Turn cold water off, remove and replace rubber washer Turn cold water faucet off and remove washer inlet hose.
  • Page 18: Connect Vent

    Turn on cold water faucet Check that the water faucets are turned on. Check for leaks Check for leaks around “Y” connector, faucets, and hoses. CONNECT VENT Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer.
  • Page 19: Complete Installation Checklist

    Adjust leveling legs If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once legs are level, make sure all four legs are snug against the ground before adjusting them. COMPLETE INSTALLATION CHECKLIST Check that all parts are now installed.
  • Page 20 W10443041B W10443042B-SP © 2012 02/12 All rights reserved Printed in U.S.A.

This manual is also suitable for:

Mede301ywMede251ygWed9151ywWed9371ywWed9051yw

Table of Contents