Final Installation - Maytag MDE5500AZW Installation Instructions Manual

Automatic dryer
Hide thumbs Also See for MDE5500AZW:
Table of Contents

Advertisement

Available languages

Available languages

At this time, make sure all gas connections
(on gas models),
exhaust
and electrical
connections
are
complete.
Plug dryer in, and check operation
by using the check
list below.
(GAS MODELS
ONLY)
The burner
may not ignite initially due to air in the gas line.
Allowing
the dryer to operate
on a heat
setting will purge the line.
If the gas does not ignite within five minutes,
turn the dryer off and wait
5 minutes.
Be sure the gas supply to the dryer has been turned
on.
In order to confirm
gas ignition,
check the exhaust
for heat.
FINAL
INSTALLATION
CHECK
LIST
Dryer is plugged
into electrical
outlet and is properly
grounded.
NOTE:
The first time power is applied
a code "PF" may be displayed.
This is normal
and can be reset by pressing
any key.
Exhaust
duct work is hooked
up and joints taped.
Plastic flexible
duct is NOT used.
Use rigid or stiff walled
flexible
metal vent material.
Dryer is level with all legs firmly on the floor, with the lock nuts tightened.
Vinyl feet have been installed.
Gas Models - gas is turned
on, there are no gas leaks.
Dryer runs, heats, shuts off.
Demonstrate
use to consumer.
HOUSEHOLD
INSTALLATION
ACCESSORIES
• Vent hood - 4" (10.16 cm) opening
- 059129
• Aluminum
pipe - 4" x 24" (10.16 cm x 60.96 cm) - 059130
• Aluminum
elbow - 4" (10.16 cm) - 059131
• Aluminum
window
plate - 15" x 20" (38.10
cm x 50.80 cm) - 4" (10.16 cm) hole - 059134
• Flexible
aluminum
vent duct - 4" (10.16
cm) diameter
- 38" (81.28 cm) length stretches
to 8' (2.44 cm) -
304353
• Clamp for flexible
aluminum
duct - 304630
• Exhaust
duct kit for base or left side exhausting
- 12001453
• Rectangular
vent kit - 059144
• Dacron
lint bag - 311353
• NATURAL
to LP conversion
kit - 306195
• LP to NATURAL
conversion
kit - 306204
• Anchor
bracket
kit - 303740
• Heating
element
conversion
kit, 208V., not for Canada-
308590
• Grounding
kit-
12001875
• Power cords - 240 v, 30 A
4' (121.9
cm
- 3-wire
5' (152.4
6' (182.9
10' (304.8
4' (121.9
5' (152.4
6' (182.9
10' (304.8
- 33001780
cm
- 3-wire - 33001822
cm
- 3-wire - 33001823
cm
- 3-wire - 33001838
cm
- 4-wire - 33001781
cm
- 4-wire - 33001824
cm
- 4-wire - 33001825
cm
- 4-wire - 33001838
For the visually
impaired,
Braille labels can be placed
on the control
panel of the appliance.
Check with your
local Association
for the Blind for information
on Braille label makers.
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents