LOCATION CONSIDERATIONS
The dryer should
be located
to permit adequate
room in front for loading the dryer, and sufficient
room behind
the dryer for the exhaust
system.
This dryer is factory-ready
for rear exhaust.
To exhaust
out the bottom or left side, use the accessory
exhaust
kit (see Accessories).
Instructions
are included
with the kit.
It is important to make sure the room has adequate make-up air. The area where the dryer is located must not
obstruct the flow of combustion
or ventilating
air.
On gas dryers, adequate
clearance
as noted on the data plate must be maintained
to insure adequate
air for
combustion
and proper operation
of the dryer.
THE DRYER
MUST
NOT BE INSTALLED
OR STORED
IN AN AREA
WHERE
IT WILL BE EXPOSED
TO
WATER AND/OR
WEATHER.
THE DRYER
AREA
IS TO BE KEPT CLEAR
AND FREE FROM
COMBUSTIBLE
MATERIALS,
GASOLINE
AND OTHER
FLAMMABLE
VAPORS
AND LIQUIDS.
A DRYER
PRODUCES
COMBUSTIBLE
LINT. THE AREA AROUND
THE DRYER
SHOULD
BE KEPT FREE OF LINT.
ALCOVE OR CLOSET iNSTALLATION
An appliance
installed
in a closet shall have no other fuel-burning
appliance
installed
in the same closet.
Each opening
area in the door must have a minimum
of 36 square
inches.
These openings
must not be obstructed.
(Louvered
door with equivalent
air
opening
is acceptable.)
0"
FRONT VIEW
CLOSET
DOOR
3"
[
(7.6 cl
0"
[
_2"
(5.1 cm)
3"
SIDE VIEW
_ 36"
sq.ins.
(91.4 cm)
36"
sq.
ins.
91.4 cm)
WARNING
-
The dryer must
be exhausted
to
the outside to
reduce
the risk
of fire when
installed in an alcove or closet.
Minimum
installation
clearances.
If possible,
more clearance
is recommended.
MOBILE HOME INSTALLATION
The installation
of the dryer in mobile homes must conform to the Manufactured
Home Construction
and Safety
Standard
Title 24 CFR, Part 32-80 {formerly the Federal standard for Mobile Home Construction
and Safety, Title
24, HUD (Part 280), 1975} for the United States,) or CSA Standards
Z240 (for Canada).
When installing
a dryer in a mobile home, provisions
for anchoring
the dryer to the floor must be made.
An
anchor
bracket
kit is available with instructions
(see Accessories).
Locate in an area that has adequate
make
up air. A minimum
of 25 square
inches (63.5 cm) of unobstructed
opening
is required.
All mobile home
installations
must be exhausted
to the outside
with the exhaust
duct termination
securely
fastened
to the mobile
home structure,
using materials
that will not support
combustion.
The exhaust
duct
may not terminate
beneath
the mobile
home.
See the section
on exhausting
for more information.