L O C ATION CONSIDERAT I O N S
The dryer should be located to permit adequate room in front for loading the dryer, and sufficient room behind
the dryer for the exhaust system.
This dryer is factory-ready for rear exhaust. To exhaust out the bottom or left side, use the accessory exhaust
kit (see Accessories). Instructions are included with the kit.
It is important to make sure the room has adequate make-up air. The area where the dryer is located must not
o b s t ruct the flow of combustion or ventilating air.
On gas drye r s, adequate clearance as noted on the data plate must be maintained to insure adequate air fo r
c o m bustion and proper operation of the drye r.
THE DRYER MUST NOT BE INSTALLED OR STORED IN AN AREA WHERE IT WILL BE EXPOSED TO
WATER AND/OR WEATHER. THE DRYER AREA IS TO BE KEPT CLEAR AND FREE FROM
COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. A DRYER
PRODUCES COMBUSTIBLE LINT. THE AREA AROUND THE DRYER SHOULD BE KEPT FREE OF LINT.

ALCOVE OR CLOSET INSTALLATION

An appliance installed in a closet shall have no other fuel-burning appliance
installed in the same closet.
Each opening area in the door must have a minimum of 36 square inches.
These openings must not be obstructed. (Louvered door with equivalent air
opening is acceptable.)
17"
(43.2 cm)
0"
0"
FRONT VIEW

MOBILE HOME INSTALLATION

The installation of the dryer in mobile homes must confo rm to the Manu factured Home Construction and Safe t y
Standard Title 24 CFR, Pa rt 32-80 {fo rm e rly the Fe d e ral standard for Mobile Home Construction and Safe t y, T i t l e
24, HUD (Pa rt 280), 1975} for the United States,) or CSA Standards Z240 (for Canada).
When installing a dryer in a mobile home, provisions for anchoring the dryer to the floor must be made. A n
anchor bra cket kit is ava i l a ble with instructions (see Accessori e s ) . Locate in an area that has adequate make
up air. A minimum of 25 square inches (63.5 cm) of unobstructed opening is required.
All mobile home installations must be exhausted to the outside with the exhaust duct termination securely
fastened to the mobile home structure, using materials that will not support combustion. The exhaust duct
may not terminate beneath the mobile home. See the section on exhausting for more information.
CLOSET DOOR
3"
(7.6 cm)
0"
2" (5.1 cm)
3"
(7.6 cm)
SIDE VIEW
36"
sq.ins.
(91.4 cm)
Minimum installation clearances. If possible,
more clearance is recommended.
36"
sq. ins.
(91.4 cm)
WARNING –
The dryer must
be exhausted to
the outside to
reduce the risk
of fire when
installed in an a l c ove or closet.