Plan Vent System
Choose
your exhaust
installation
type
Recommended
exhaust installation:
©
A.
Dryer
E
Rigid metal or
B
Elbow
flexible metal vent
C.
Wall
G.
Vent length
D.
Exhaust hood
necessary to
E.
Clamps
connect elbows
H.
Exhaust outlet
Fire Hazard
Cover unused exhaust
holes with a manufacturer's
exhaust cover kit,
Contact your local dealer.
Failure to fellow these instructions
can result in death,
fire, electrical shock, or serious injury.
Optional
exhaust
installations:
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. If you prefer, you may contact your
local dealer to have the dryer converted.
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Special
provisions
for mobile
homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
!
Determine
vent path:
[] Select route that will provide straightest and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90 ° turns as possible.
Determine
vent length and elbows
needed
for best
drying
performance:
[] Use the following "Vent System Chart" to determine type
of vent material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Chart".
Exhaust systems longer than those specified will:
[] Shorten life of dryer.
[] Reduce performance,
resulting in longer drying times
and increased energy usage.
The "Vent System Chart" provides venting requirements
that will help achieve best drying performance.
Vent System
Chart
Number
of
Type
Box/Iouvered
Angled
90 ° elbows
of vent
hoods
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6 m)
3
4
2
Rigid metal
Rigid metal
Rigid metal
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations have a 90 ° turn
inside the dryer. To determine maximum exhaust length, add
one 90 ° turn to the chart.
11