KitchenAid KDRU707VSS01 Installation Instructions Manual page 15

30", 36", 48" commercial style dual fuel convection range
Hide thumbs Also See for KDRU707VSS01:
Table of Contents

Advertisement

Available languages

Available languages

3.
Pull tube
to ensure
it is secured.
[]
:! []
Water supply
tubing to range
Water
supply
connection
Shutoff
J
valve
Yellow
WATER
Water supply
tubing
to cold water supply
Blue
WATER
OUT
4. Route flexible codes approved water supply line through
undersink cabinet and oven cabinet cutout.
5. Connect the flexible codes approved water supply line to the
range copper tubing, using a ¼" to 1_,,water supply union.
C
E
F
A. To home water supply
B. Rear of cabinet cutout
C. Flexible codes approved
water supply fine from home
water supply
D. ¼" to ¼" water supply union (supplied in water filter kit)
E. Oven copper tubing
F Range front
6. Turn on water supply.
7. Check all connections for leaks.
NOTE: No flushing or conditioning of the water filter is required
prior to use.
Explosion
Hazard
Use a new CSA International
approved
gas supply
line.
Install a shut=off valve.
Securely
tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples
of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
1. Assemble flexible connector from gas supply pipe to pressure
regulator located in the middle rear of the range.
2. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
3. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
4. Use a _%e"combination
wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
B
C
/
D
/
/
H
G
F
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have Y2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F Y2" or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter
Complete
Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve