Installation Requirements; Parts; Location Requirements; Electrical Requirements - KitchenAid KECC548BSS0 Installation Instructions Manual

Electric cooktop
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
REQUIREMENTS
Gather the required parts before starting installation. Read and follow the instructions
provided with any tools listed here.
Parts Supplied
Mounting clips (4)
UL listed or CSA approved wire cable
Parts Needed
UL listed or CSA approved connector for 1/2"(1.3 cm)
diameter conduit
UL listed wire connectors
Check local codes. Check existing electrical supply. See the
"Electrical Requirements"
section.
It is recommended
that all electrical connections
be made by a
licensed, qualified electrical installer.
IMPORTANT:
Observe all governing codes and ordinances.
When installing cooktop,
use minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
The cooktop must be a specified cooktop that is approved to
be installed either alone or over an undercounter
built-in
oven. Check the cooktop base for an approved installation
label. If you do not find this label, contact your dealer to
confirm that your cooktop is approved.
The cooktop must be installed in a level countertop.
Ovens approved for this type of installation will have an
approval label located on the top of the oven. If you do not
find this label, contact your dealer to confirm that your oven is
approved.
Refer to oven manufacturer's
Installation
Instructions for approval for built-in undercounter
use and
proper cutout dimensions.
The cooktop should be installed away from strong draft
areas, such as windows, doors, fans or strong heating vents.
The cooktop should be located for convenient use in the
kitchen.
Use the countertop opening dimensions that are given with
these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.
Grounded electrical supply is required. See "Electrical
Requirements"
section.
IMPORTANT: To avoid damage, check with your builder or
cabinet supplier to make sure that the materials used will not
discolor, delaminate or sustain other damage.
Product
Dimensions
A
\
C
A. 20" (51.0 cm)
B. 24" (61.0 cm)
C. 1½" (4.0 cm)
Cabinet
Dimensions
IMPORTANT: If installing a range hood or microwave hood
combination
above the cooktop, follow the range hood or
microwave hood combination
installation instructions
for
dimensional clearances above the cooktop surface.
C
I
I
G
A. 23 ½" (60.0 cm)
B. Combustible
area above countertop
(shown by dashed box
above)
C. 30" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered
wood or metal cabinet
(24" [61.0 cm] minimum
clearance if bottom of wood or metal
cabinet is covered by not less than ¼" [0.6 cm] flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" [..0.04cm] stainless steel, or 0.024" [0.06 cm] aluminum
or 0.020
[0.05 cm] copped
D. 13" (33.0 cm) recommended
upper cabinet depth
E. 2" (5.1cm)
F. 19_" +/-
He" (49.2 +/- 0.16 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to
countertop
within minimum
horizontal clearances to cooktop
H. Junction box or outlet: 7" (17.8 cm) minimum from top of
countertop
I. Junction box or outlet: 9" (23.0 cm) maximum from right side of
cabinet
J. 22" +/- He" (56.2 +/- 0.16 cm)
K. 4" (10.0 cm) minimum distance to nearest left side combustible
surface above cooktop
L. 2" (5.0 cm) minimum clearance between back wall and
countertop
2

Advertisement

Table of Contents
loading