For Cooktops With a 3-Wire Cable:
If Your Home Has:
And You Will Be
Go to Section:
Connecting To:
4-wire direct
A fused
4-Wire Cable from
disconnect
or
Power Supply to
circuit breaker
3-Wire Cable from
box
Cooktop
(12.7 crn)
3-wire direct
A fused
3-Wire Cable from
disconnect
or
Power Supply to
circuit breaker
3-Wire Cable from
box
Cooktop
4-Wire Cable from Power Supply to 3-Wire Cable from
Cooktop
IMPORTANT: Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
conductor to the neutral (white) junction box wire:
A
B
F
G
H
D
I
E
J
A. 4-wire cable from power supply
F. Junction box
B. Red wire from power supply
G. White wire from power supply
C• White wire from cooktop cable
H• UL fisted wire connector
D. Green (or bare) ground wires
I. Black wires
from cooktop
cable
J• UL listed or CSA approved conduit
E• 3-wire cable from cooktop
connector
with wire bushing
1. Disconnect
power
2. Remove junction box cover if present•
3. Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit
connector•
4. Tighten screws on conduit connector, if present•
5. Connect the 2 black wires together using the UL listed wire
connectors•
6. Connect the red wire (in the junction box) to the white wire
from the cooktop cable using the UL listed wire connectors•
7. Connect the green or bare ground wire from the cooktop
cable to the green or bare ground wire (in the junction box)
using the UL listed wire connectors•
8. Put a UL listed wire connector
on the end of the white wire
from the power supply•
NOTE: Do not connect the bare ground wire to the neutral
(white) wire in the junction box.
9. Install junction box cover•
10. Reconnect power•
3-Wire Cable from Power Supply to 3-Wire Cable from
Cooktop
IMPORTANT:
Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground
conductor
to
the neutral (white) junction box wire:
E
A. 3-wire cable from power
supply
B• Red wire from power supply
C. White wire from cooktop cable
D. Green (or bare) ground wire
from cooktop
cable
E• 3-wire cable from cooktop
F
G
H
J
F. Junction box
G. White wire from power supply
H• UL listed wire connector
I. Black wires
J• UL listed or CSA approved
conduit connector with wire
bushing
1. Disconnect
power
2. Remove junction box cover, if present•
3. Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit
connector•
4. Tighten screws on conduit connector
if present•
5. Connect the 2 black wires together using the UL listed wire
connectors•
6. Connect the red wire (in the junction box) to the white wire
from the cooktop cable using the UL listed wire connectors•
7. Connect the green or bare cooktop cable wires to the white
(neutral) wire in the junction box using the UL listed wire
connectors•
8. Install junction box cover•
9. Reconnect power•