KitchenAid KGCC566RBL03 Installation Instructions Manual page 4

30" (76 cm) and 36" (91.4 cm) gas built-in cooktop
Hide thumbs Also See for KGCC566RBL03:
Table of Contents

Advertisement

Available languages

Available languages

Emectricat
Shock Hazard
Plug intoa grounded 3 prong outlet.
Donotremove ground prong.
Donotuseanadapter.
Donotusean
extension
cord.
Faimure to follow these instructions
can resumt in death,
fire, or emectrical shock.
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70 or
Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that
will not operate if plugged into an outlet that is not properly
polarized.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended.
It is recommended
that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120 volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See
"Wiring Diagrams" section.
Explosion
Hazard
Use a new CSA gnternational
approved
gas supply
mine.
Install a shut-off
valve.
Securety
tighten
all gas connections,
ff connected
to LP, have a qua{ified
person make sure
gas pressure
does not exceed 14" (36 cm) water
comumn,
Exampmes of a quamified person
include:
licensed heating
personneB,
authorized
gas company
personnel,
and
authorized
service
personnel
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances.
In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
Type of Gas
Natural Gas:
This cooktop is design-certified
by the CSA International for use
with Natural gas or, after proper conversion, for use with LP gas.
This cooktop is factory set for use with Natural gas. To convert
to LP gas, see the Gas Conversion instructions
provided in the
literature package. The model/serial rating plate located on
the underside of the burner box has information on the types
of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas
supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See the Gas
Conversion instructions provided in the literature package.
Gas Supply
Line
Provide a gas supply line of 3/4"(1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds
that
resist the action of LP gas must be used. Do not use
TEFLON _t tape. With LP gas, piping or tubing size can be 1/2"
minimum. Usually, LP gas suppliers determine the size and
materials used in the system.
1-CeTEFLON is a registered trademark
of E.I. Du Pont De Nemours and Company.