KitchenAid KDRS807XSP01 Installation Instructions Manual page 16

30" (76.2 cm) freestanding and slide-in dual fuel ranges
Hide thumbs Also See for KDRS807XSP01:
Table of Contents

Advertisement

Available languages

Available languages

Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
5. Use a hex or Phillips screwdriver to connect the bare (green)
ground wire to the range with the ground-link
screw and
ground-link
section. The ground wire must be attached first
and must not contact any other terminal.
6. Use 3/8"nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
A
B
'i
C
A. 10-32 hex nut
B. Line 2 (red)
C. Bare (green) ground wire
D. Ground-link
screw
D
E
E. Neutral (white) wire
F. Line 1 (black)
G. Terminal lug
7. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection:
Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the wires through the conduit on cord/conduit
plate on
bottom of range. Allow enough slack to easily attach the
wiring to the terminal block.
A
............. ii
B
2.
Attach terminal lugs to line 2 (red), bare (green) ground, and
line 1 (black) wires. Loosen (do not remove) the setscrew on
the front of the terminal lug and insert exposed wire end
through bottom of terminal lugs. Securely tighten setscrew to
torque as shown in the following Bare Wire Torque
Specifications
chart.
A
!
!
I
C
D
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Bare (green) ground wire
E. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
3. Use 3/8"nut driver to connect the bare (green) ground wire to
the center terminal block post with one of the 10-32 hex nuts.
B
F
E
D
C
A. 10-32 hex nut
B. Line 2 (red)
C. Ground-link
screw
D. Bare (green) ground wire
E. Line 1 (black)
F. Terminal lug
4. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
F
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
G. Metal ground strap
16

Advertisement

Table of Contents
loading