Natural Gas - KitchenAid KDRP467KSS0 Installation Instructions Manual

36" professional dual fuel range with self-cleaning thermal/convection oven
Hide thumbs Also See for KDRP467KSS0:
Table of Contents

Advertisement

Available languages

Available languages

G8$ $U
Explosion
Hazard
Use a new AGA or CSA approved
gas supply
line.
install a shut-off
valve.
Securely
tighten alt gas
con nections.
if connected
to LP, have a
qualified
person
make sure gas
pressure
does not exceed 14"
(35.6 cm) water column.
Examples
of a qualified
person include
licensed heating
personnel,
authorized
gas company
personnel,
and authorized
service
personnel.
Failure to do so can result in
death, explosion, or fire.
Observe
all governing
codes
and
ordinances,
Important:
Range
cooktop
must be
connected
to a regulated
gas suppiyo
Am
This installation must conform
with local codes and ordinances. In the
absence of local codes, installations must
conform with American National
Standard, National Fuel Gas Code
ANSI Z223.1 -- latest edition* or
CAN/CGA-B149 -- latest edition*
installation codes.
input ratings shown on the
model/serial rating plate are for elevations
up to 2,000 feet (610 m). For elevations
above 2,000 feet (610 m), ratings are
reduced at a rate of 4% for each 1,000
feet (305 m) above sea level. (Not
applicable for Canada.)
C
mThe range is equipped for use with
NATURAL gas. It is design=certified by
International Approval Services (I.A.S.) for
NATURAL and LR gases with appropriate
conversion. The model/serial rating plate,
located on the surface below the control
panel, has information on the type of gas
that can be used. If this information does
not agree with the type of gas available,
check with the local gas supplier.
L.R Gas:
No attempt shall be made to convert the
cooktop from the gas specified on the
model/serial rating plate for use with a
different gas without consulting the
serving gas supplier. Conversion must be
done by a qualified service technician. To
convert to LR gas, use LR gas
conversion kit part no. 4453151. The parts
for this kit are in the literature package
supplied with range.
Provide a gas supply line of 3/4"
(1.9 cm) rigid pipe to the range location. A
smaller size pipe on long runs may result
in insufficient gas supply. Pipe-joint
compounds, appropriate for use with LR
gas, must be used. With LR gas, piping or
tubing size can be 1/2" (1.3 cm) minimum.
LR gas suppliers usually determine the
size and materials used on the system.
E
E if local codes permit, a new AGA
or CSA design-certified, 4-5 foot (122-
152.4 cm)long, 5/8" (1.6 cm) i.D., flexible
metal appliance connector is
recommended for connecting this range
to the gas supply line. Do Not kink or
damage the flexible tubing when moving
the range. A 1/2" (1.3 cm) male pipe
thread is needed for connection to
pressure regulator female pipe threads.
F
gas supply
line
E The supply line shall be equipped
with an approved shutoff valve. This valve
should be located in the same room, but
external to the range, and should be in a
location that allows ease of opening and
closing. Do Not block access to the
shutoff valve.
G
m if rigid pipe
_T
is used as a gas
supply line, a combination of pipe
U!
fittings must be used to obtain an in-line
connection to the range. All strains must
be removed from the supply and fuel lines
so range will be level and in line.
E The regulator must be checked at a
minimum 1=inch (25.4 mm) water column
above the set pressure. The inlet pressure to
the regulator should be as follows for
operation and checking the regulator setting:
NATURAL
GAS:
Manifold
pressure
-
5 inches (12.7 cm) W,C,
Maximum
pressure-
14 inches (35,6 cm) WoC,
L,P. GAS:
Manifold
pressure
-
10 inches
(25,4 cm) W,C,
Maximum
pressure-
14 inches
(35,6 cm) W,C,
m Line pressure testing:
Testing above 1/2 psi (3.5 kPa) (gauge}
The range and its individual shutoff valve
must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures
greater than 1/2 psig (3=5kPa).
Testing at 1t2 psi (3.5 kPa) (gauge}
Or lower
The range must be isolated from the gas
supply piping system by closing its
individual manual shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psig (3=5kPa)=
Copies of the standards listed may be
obtained from:
* CSA International
8501 East Pleasant Valley Road
Cleveland,
Ohio 44131-5575