KitchenAid KDRS807SSS00 Installation Instructions Manual page 7

30" (76.2 cm) freestanding and slide-in dual fuel ranges
Hide thumbs Also See for KDRS807SSS00:
Table of Contents

Advertisement

Available languages

Available languages

Ifcodes permit and a separate ground w ire isused, i tis
recommended
thata qualified electrical installer determine that
theground p athisadequate and wire gauge isinaccordance
withlocal c odes.
Donotuseanextension cord.
Besure that t heelectrical connection andwire size areadequate
andinconformance
withtheNational Electrical Code, ANSI/
NFPA 7 0-latest edition and alllocal c odes a ndordinances.
Acopyoftheabove c ode standards canbeobtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA 02269
WARNING: Improper connection oftheequipment-grounding
conductor canresult inariskofelectric s hock. Check w itha
qualified electrician orservice technician ifyouareindoubt a sto
whether theappliance isproperly grounded. Donotmodify t he
power supply cordplug, I fitwillnotfittheoutlet, have aproper
outlet i nstalled byaqualified e lectrician.
This range i smanufactured
withtheneutral terminal connected
tothecabinet. Use a 3-wire, ULlisted, 40-amp p ower supply
cord(pigtail); oriflocal c odes d onotpermit ground t hrough t he
neutral, usea4-wire power s upply c ord rated at250 volts,
40amps andinvestigated
forusewithranges.
Electrical Connection
Toproperly install yourrange, youmust d etermine thetype of
electrical connection youwill b eusing and follow theinstructions
provided forit here.
• Range m ust b econnected totheproper electrical voltage
and frequency asspecified onthemodel/serial
number rating
plate. T he model/serial
rating plate islocated i nside theoven
door o ntheright-hand side oven door t rim. R efer tothe
figures i nthe"Product Dimensions"
section o fthe"Location
Requirements"
section,
When a4-wire or3-wire, single phase 1 20/240 volt,60Hz,
AConly electrical supply isavailable, a50-amp m aximum
circuit p rotection isrequired. When a4-wire o r3-wire s ingle
phase 1 20/208 volt60Hz, A Conlyelectrical supply i s
available, a40-amp m aximum c ircuit p rotection isrequired,
fused onbothsides oftheline.
• Atime-delay fuse orcircuit b reaker isrecommended.
The range c anbeconnected directly t othefused disconnect
(orcircuit b reaker box) t hrough f lexible o rnonmetallic
sheathed, copper oraluminum c able. See"Electrical
Connection."
• Allow 2to3ft (61.0 cmto91.4 cm)ofslack intheline sothat
therange c anbemoved i fservicing isever n ecessary.
• AULlisted conduit connector must b eprovided ateach end
ofthepower supply c able (attherange a ndatthejunction
box).
• Wire sizes andconnections
must c onform withtherating of
therange (40 amps).
• The wiring diagram islocated o ntheunderside ofthestorage
drawer orbelow thewarming drawer ina clear p lastic b ag.
If connecting
to a 4-wire system:
This range is manufactured
with the ground connected to the
cabinet. The ground must be revised so the green ground wire of
the 4-wire power supply cord is connected to the cabinet. See
"Electrical Connection."
Grounding through the neutral conductor
is prohibited for new
branch-circuit
installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250 volt, 40-amp, range power supply
cord (pigtail) must be used. This cord contains 4 copper
conductors
with ring terminals or open-end spade terminals with
upturned ends, terminating
in a NEMA Type 14-50R plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting
to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire,
250 volt, 40-amp range power supply cord (pigtail). This cord
contains 3 copper conductors
with ring terminals or open-end
spade terminals with upturned ends, terminating
in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)