Direct
Wire
Connection
Direct wire strain relief
A
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads.
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
if your wiring looks like this:
4-wire direct connection:
Go to "4-Wire Direct Connection"
on
this page.
4=wire Direct Wire Connection
IMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit 3-wire
connections.
1, Prepare your 4=wire cable for direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
washer/dryer
may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 11/2'' (38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
wire and neutral
wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
3-wire direct connection:
Go to "3-Wire Direct Connection"
on
page 15.