Bottom Return Air Inlet/Horizontal Installation; Filter Arrangement; Suspended/Platform Furnace Support; Roll-Out Protection/Bottom Return Air Inlet/Side Return Air Inlet - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

FURNACE
APPROVED
COIL ASSEMBLY
OR
COIL BOX
COMBUSTIBLE
FLOORING
I
SHEET METAL _
PLENUM
FLOOR
OPENING
12
\\\\_
A08556
Fig. 13 - Furnace, Plenum, and Coil Assembly or Coil Box
Installed on a Combustible
Floor
Bottom
Return
Air Inlet
These furnaces
are shipped
with bottom
closure
panel installed
in
bottom
return-air
opening.
Remove
and discard
this panel when
bottom
return
air is used.
To remove
bottom
closure
panel,
perform
the following:
1. Tilt or raise furnace
and remove
2 screws
holding
bottom
filler panel. (See Fig. 9.)
2. Rotate
bottom
filler panel
downward
to release
holding
tabs.
3. Remove
bottom
closure
panel.
4. Reinstall
bottom
filler panel and screws.
HORIZONTAL
INSTALLATION
FIRE,
EXPLOSION,
AND
CARBON
MONOXIDE
POISONING
HAZARD
Failure to follow this warning could result in personal
injury, death, or property damage.
Do not install the furnace on its back or hang furnace with
control compartment
facing downward.
Safety control
operation
will
be adversely
affected.
Never
connect
return-air ducts to the back of the furnace.
The furnace can be installed horizontally in an attic or crawl
space on either the left-hand (LH) or right-hand
(RH) side. The
furnace can be hung from floor joists, rafters or trusses or
installed on a non-combustible
platform, blocks, bricks or pad.
Suspended Furnace Support
The furnace may be supported under each end with threaded rod,
angle iron or metal plumber's strap as shown. (See Fig. 15 and
16.) Secure
angle
iron to bottom
of furnace
as shown.
Heavy-gauge
sheet metal straps (plumber's straps) may be used
to suspend the furnace from each bottom corner. To prevent
screws from pulling out, use 2 #8 x 3/4-in. (19 ram) screws into
the side and 2 #8 x 3/4-in. (19 ram) screws in the bottom of the
furnace casing for each strap. (See Fig. 15 and 16.)
If the screws are attached
to ONLY
the furnace
sides and not the
bottom,
the straps
must be vertical
against
the furnace
sides and
not pull away from the furnace
sides, so that the strap attachment
screws are not in tension
(are loaded in shear) for reliable
support.
Platform
Furnace
Support
Construct
working
platform
at location
where all required
furnace
clearances
are met, (See Fig, 2 and 170 For furnaces
with 1-in,
(25 ram)
clearance
requirement
on side,
set furnace
on non-
combustible
blocks,
bricks
or angle
iron,
For
crawl
space
installations,
if the furnace
is not suspended
from the floor joists,
the ground
underneath
furnace
must be level and the furnace
set
on blocks
or bricks,
Roll- Out Protection
Provide
a minimum
17-3/4
in, x 22 in, (451 x 559 ram) piece of
sheet metal
for flame roll-out
protection
in front of burner
area
for
furnaces
closer
than
12
inches
(305
ram)
above
the
combustible
deck
or suspended
furnaces
closer
than
12 inches
(305 ram) to joists,
The sheet metal MUST
extend underneath
the
furnace
casing by 1 in, (25 ram) with the door removed,
The bottom
closure
panel on furnaces
of widths
17-1/2
in, (445
ram) and larger may be used for flame roll-out
protection
when
bottom
of furnace
is used for return
air connection,
See Fig, 17
for proper
orientation
of roll-out
shield,
Bottom
Return
Air Inlet
These furnaces
are shipped
with bottom
closure
panel installed
in
bottom
return-air
opening,
Remove
and discard
this panel when
bottom
return
air is used,
To remove
bottom
closure
panel,
perform
the following:
1, Tilt or raise furnace
and remove
2 screws
holding
bottom
filler panel, (See Fig, 90
2, Rotate
bottom
filler panel
downward
to release
holding
tabs.
3. Remove
bottom
closure
panel.
4. Reinstall
bottom
filler panel and screws.
Side Return
Air Inlet
These furnaces
are shipped
with bottom
closure
panel installed
in
bottom
return-air
opening.
This panel
MUST
be in place when
side return air inlet(s) is used without
a bottom
return air inlet.
Not
all horizontal
furnaces
are
approved
for
side
return
air
connections.
(See Fig. 20.)
FILTER
ARRANGEMENT
CARBON
MONOXIDE
AND POISONING
HAZARD
Failure to follow this warning
could result in personal
iniury, death and/or property damage.
Never operate a furnace without a filter or with filter access
door removed.
There are no provisions
for an internal
filter rack in these
furnaces.
Refer to the instructions supplied with accessory Media Cabinet
for assembly and installation options.
This furnace requires a field-supplied
external filter rack or a
suitable field-supplied
substitute, such as the media cabinet.
See
Table 17 for accessory list.
Refer to the instructions
supplied with external filter rack for
assembly and installation options.
12