Horizontal Left Application - Vent Elbow Right Then Up/Vent Elbow Up/Vent Elbow Right; Horizontal Right Application - Vent Elbow Right/Left Then Up/Left - Payne PG8MAA Installation And Operating Instructions Manual

Series 140/e single-stage deluxe, induced-combustion 4-way multipurpose gas furnace
Table of Contents

Advertisement

SEE NOTES: 1,2,4,5,7,8,9
on the page
following
these figures
A03214
Fig.
35
-
Horizontal
Left
Application-Vent
Elbow
Right
then
Up
° /A
i
,\/,
SEE NOTES: 1,2,4,5,7,8,9
on the page
following these figures
A03215
Fig.
36
-
Horizontal
Left
Application-Vent
Elbow
Up
SEE NOTES: 1,2,4,7,8,9 on the page
following these figures
A03218
Fig.
38
-
Horizontal
Right
Application-Vent
Elbow
Right
SEE NOTES:
1,2,4,5,7,8,9
on the page
following
these
figures
A03219
Fig. 39
-
Horizontal
Right
Application-Vent
Elbow
Left
then
Up
O
SEE NOTES: 1,2,4,5,7,8,9 on the page
following these figures
A03216
Fig. 37
-
Horizontal
Left
Application-Vent
Elbow
Right
SEE NOTES: 1,2,4,5,7,8,9
A02068
Fig.
40
-
Horizontal
Right
Application-Vent
Elbow
Left
NOTES FOR FIGS. 33 - 45
1. For common
vent, vent
connector
sizing
and vent material,
use the NFGC.
2. Immediately
increase
to 5-in.
(127 mm) or 6-in.
(152 mm) vent connector
outside
furnace
casing
when
5-in.
(127 mm) vent connector
is required,
refer to Note
1 above.
3. Side
outlet
vent
for upflow
and
downflow
installations
must
use Type
B vent
immediately
after exiting
the furnace,
except
when
field-approved
Downflow
Vent Guard
Kit, is used in the downflow
position.
See Table
17 for accessory
list.
4. Type-B
vent where
required,
refer
to the Note
1 above.
5. A 4-in.
(102 mm) single-wall
(26 ga. minimum)
vent must
be used inside
furnace
casing
and when the field-approved
Downflow
Vent Guard
Kit is
used external
to the furnace.
See
Table
17 for accessory
list.
6. Accessory
Downflow
Vent Guard
Kit required
in downflow
installations
with
lower
vent configuration.
See Table
17 for accessory
list.
7. Chimney
Adapter
Kit may be required
for exterior
masonry
chimney
applications.
Refer
to Chimney
Adapter
Kit for sizing
and complete
application
details.
See Table
17 for accessory
list.
8. Secure
vent connector
to furnace
elbow
with (2) corrosion-resistant
sheet
metal
screws,
spaced
approximately
180 ° apart.
9. Secure
all other
single
wall vent connector
joints
with (3) corrosion
resistant
screws
spaced
approximately
120 ° apart.
Secure
Type-B
vent connect-
ors per vent
connector
manufacturer's
recommendations.
10.
The total height
of the vent and connector
shall be at least seven
ft. (2.1 M) for the 154,000
Btuh
gas input rate model
when
installed
in a downflow
application
with furnace
elbow
turned
to left side with
the connector
elbow
outside
furnace
casing
pointing
upward.
(See Fig. 31.)
31