Connection Diagram 1 Door Station / 1 Room Station - iCentral 10.2 Premium Installation & Operation Manual

10.2 premium video intercom system
Table of Contents

Advertisement

Connection diagram 1 door Station / 1 room Station

door Lock Connection, Method 1
Notes
1. The Room Station provides power for the electric door strike.
2. one extra pair of wires is required between the door and the Room Station.
This method eliminates the need to provide a dedicated power supply for the electric
door strike.
100-958
dooR STATIoN
PW
gNd
Ad
Vd
kEy1
kEy2
NoT
uSEd
door Lock Connection, Method 2
Notes
1. The electric door strike is unlocked by a pair of dry relay contacts at the door Station.
2. A dedicated power supply is required for the electric door strike.
3. If the door strike power supply is located near the front door then only 4 wires are
required between the door and the Room Station.
4. This method provides lower security as the door strike can be operated by short-
circuiting the kEy1 & kEy2 wires at the back of the door station.
100-958
dooR STATIoN
PW
gNd
Ad
Vd
kEy1
kEy2
12VdC ElECTRIC
dooR STRIkE
10.2 RooM STATIoN
MASTER Setting
Both switches oN
MASTER Setting
Both switches oN
dooR STRIkE
PoWER SuPPly
840-003 or equivalent
100-974
13.8V-
Vd
13.8V+
Ad
gNd
gNd
dATA
loCk1
PWR1
Vd3
gNd
PWR3
Ad1
gNd
Vd1
Ad3
PWR2
Vd4
gNd
PWR4
Ad2
gNd
Vd2
Ad4
100-974
10.2 RooM STATIoN
13.8V-
Vd
13.8V+
Ad
gNd
gNd
dATA
loCk1
PWR1
Vd3
gNd
PWR3
Ad1
gNd
Vd1
Ad3
PWR2
Vd4
gNd
PWR4
Ad2
gNd
Vd2
Ad4
up to 15m cable length use 4 core screened cable for audio,
video and power. over 15m cable length, use Rg59 coax cable
for Vd and gNd.
Max. cable distance: Master-Slave: 60m / door-Master: 80m
See page 4 for further detail.
9
840-003
PoWER SuPPly
13.8VdC
12VdC ElECTRIC
dooR STRIkE
PoWER SuPPly
840-003