Section T wo:
Transportation (DOT).The cylinder must be provided
with a shut off valve terminating in an LP gas supply
cylinder valve outlet specified, as applicable, for
connection type QCC1 in the standard for compressed
gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
Manifold pressure: (operating):10" water column (W.C.),
(non-operating) :11.2" water column (W.C.).
LP GAS HOOK-UP:
Ensure that the black plastic grommets are in place and
that the hose does not come into contact with the heat
shield or the grill head .
CONNECTION:
PCA-2600L orifice for use with LP gas come equipped
with a high capacity hose/regulator assembly for
connection to a standard 20 lb. LP cylinder (18-1/4"
high, 12-1/4" diameter).The (Type 1) LP tank is
included.
FIG.11
Carefully place LP tank onto bottom panel
of cart.
GAS HOOK-UP
Hose / regulator assembly is shipped ready for
connection to LP tank.
FIG.12
Attach " Tee" fitting to male end of grill hose.
7
FIG.10
Type QCC1 regulator with
"Tee" fittings

Hide quick links: