Error mode
The charger enters error mode before start in the following situations:
•
The battery is connected with poles reversed to the charger's terminals.
•
The terminals on the charger are short-circuited.
Error mode before start is reset by removing the error situation. The charger restarts in
the latest selected mode.
The charger enters steady error mode in the following situations:
•
The charger's analysis function has interrupted charging.
•
The charger is overloaded in Supply mode.
•
The charger has been in start mode longer than maximum time.
restarts in the latest selected mode.
BULK CHARGING TIME
Battery size (Ah)
14
50
90
150
12 • US
Time to ~80% charge (h)
2
6–7
11–13
20–22
Need help?