Bulk Charging Time - CTEK MULTI US 3300 User Manual

For lead-acid batteries 2–90ah
Hide thumbs Also See for MULTI US 3300:
Table of Contents

Advertisement

Desulphation: Desulphation with pulsing for sulphated batteries.
Bulk: Charging where about 80% of the energy is returned. The charger delivers an
almost constant current until the battery voltage reaches the set level.
Absorption: Charging up to almost 100%. The charge current tapers and the voltage is
kept constant at the set level.
Pulse: Maintenance charge. The charging process ranges between 95% and 100%. The
battery receives a pulse if the voltage falls. This stage will keep your battery in a good
condition if it is not being used.

BULK CHARGING TIME

The table shows the duration of the Bulk step up to about 80% state of charge. The time
for the Absorption should be added.
Battery size (Ah)
2
8
14
50
90
10 • US
Mode
Time (h)
2–3
8–10
3–4
12–14
23–26

Hide quick links: