Seal The Openings; Connect The Range To The Gas Supply - Crosley CRP3160GWWD Installation Instructions Manual

30" models with preset lp/propane gas fuel and sealed top burners only
Table of Contents

Advertisement

Available languages

Available languages

C.
Level and Position Range- Level range by adjusting the
(4) leveling legs with a wrench. Note: A minimum clearance
of 1/8" is required between the bottom of the range and the
leveling leg to allow room for the bracket. Use a spirit level
to check your adjustments. Slide range back into position.
Visually check that rear leveling leg is inserted into and
fully secured by the Anti-Tip Bracket by removing lower
panel or storage drawer. For models with a warmer drawer
or broiler compartment,
grasp the top rear edge of the
range and carefully attempt to tilt it forward.
__
Cen_erline
of flange
I
--_ 11-1/2" _-
I,_7 I
o
I
"1
i
fRecommended
Area for'_ i
120V Outlet on Rear of I
Wall and Area for Thru| l
"_'_'-_ 2 3"
_--i_-_
i
the Wall Connection
of _
!
i
""_-_: ..d _
Pipe Stub and Shut Off| ]
22'
i
i
_
I
[
. Valve is Shaded Area. J
-41_"-i_,_,_:__1
_"
(Recommended
Area for Thru _ " " -_--_
a
|
the Floor Connection
of
/
Edge
[Pipe Stub and Shut Off Valve. )
2. Provide an adequate
gas supply.
This unit is pre-set to operate on 10" LP/Propane gas manifold
pressure. A convertible pressure regulator is connected to the
manifold and MUST be connected
in series with the gas
supply line.
Care must be taken during installation of range not to obstruct
the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water column
pressure. The inlet pressure to the regulator must be at least
1 inch greaterthan regulator manifold pressure. Examples; If
regulator has been set for LP/Propane gas 10 inch manifold
pressure, inlet pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted according to
the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
3. Seal the openings.
Seal any openings in the wall behind the range and in the floor
under the range after gas supply line is installed.
4. Connect
the range to the gas supply.
To prevent leaks, put a pipe joint sealant on all male (outside)
pipe threads.
Your regulator is in the location shown below.
Do not allow regulator
toturn on pipe when
tightening
fittings.
Gas
Regulator
Gas
Regulak
-_
Service
_Gas
Shut-Off Valve
)
(shown in the
__
"ON" position.)

Advertisement

Table of Contents
loading

Table of Contents