Download Print this page

Frigidaire FFF335ESF Installation Instructions Manual page 4

30" electric range with 4 wire, 3 phase, 380/220 volt, "y" connected, 50 hz. systems with ac service
Hide thumbs Also See for FFF335ESF:

Advertisement

Available languages

Available languages

4.
Power
Supply
Cord
Kit
You must provide
an adequate
electrical
supply as required
for
your
range.
Check with
local
utilities
for
governing
electrical
codes and ordinances.
Know
where
your
range
electrical
supply
disconnect
is
located.
A four (4) wire, three
(3) phase, 380/220
volts, "Y"
connected,
50 Hertz, AC electrical
system
(properly
fused)
must
be provided.
Only
a qualified
technician
who
is familiar
with
the
installation
of electric
ranges
should
install
and connect
the range
to the house
wiring
system.
5. Electrical
Connection
to Range
The rear access cover must be removed.
To remove,
loosen
center
screw
(one screw)
and
remove
access cover.
The
terminal
block will then
be accessible.
Cover
Rear
of Range
NOTE:
Range is shipped
from factory
with
1-3/8" dia. hole
as shown.
To
use either
7/8"
dia.
hole
or
1-1/8"
dia.
knockouts:
1.
Using a 1/4" socket driver,
remove eight (8) screws from
Rear Wall
Shield to release from
the unit
(as shown).
Save the screws for step #7 below.
2.
Again using the 1/4" socket driver,
remove one (1) blunt
point screw used to secure the Cable Mounting
Plate to
the Rear Wall Shield.
Save the screws for step #6.
3.
Remove the Cable Mounting
Plate from
the Rear Wall
Shield
by sliding
the plate
out of the pockets.
4.
Ifa 1-1/8"dia.
holeisrequired,"punch-out"theknockout.
5.
Rotate
the plate
180 degrees
so that
the desired
hole
is placed
on top of the opening
located
on the bottom
flange
of the Rear Wall Shield.
6.
Slide
the
Cable
Mounting
Plate
into
the
Rear Wall
Shield.
Re-secure
using the blunt
point
screw removed
from
step #2 above.
7.
Reassemble
the Rear Wall Shield to the unit using eight
(8) screws
removed
from
step #1 above.
6.
Wiring
Instructions
a.
Remove the loose nuts on the terminal
block studs (A
3/8" nut driver
or socket
is useful
for this purpose).
NOTE:
DO NOT LOOSEN THE NUTS WHICH SECURE THE
FACTORY INSTALLED RANGE WIRING TO THE TERMINAL
BLOCK WHILE CONNECTING
THE RANGE. ELECTRICAL
FAILURE OR LOSS OF ELECTRICAL CONNECTION
MAY
OCCUR IF THE NUTS ARE LOOSENED.
b.
Connect
power
supply
wires
to terminal
block
as
illustrated.
To ensure protection
for the operator,
as well as the range,
the range must be grounded
to the equipment
ground
line,
as shown.
c.
Install
and tighten
nuts
securely
on cable
terminals.
Install access cover.
1-1/8"
Dia.
7/8" Dia.
_-"
Knockout
Hole
(See Chart)
(See Chart)
_"
.o ntin .
Hole
(See Chart)
Pocket
for Cable
Mounting
Plate
If a different
diameter
hole is required,
please
follow
the
steps listed:
4

Advertisement

loading