5. Electrical
Connection
Requirements
This appliance
must be properly installed and
grounded by a qualified technician
in accordance
with
the National Electrical Code ANSl/NFPA
No. 70--latest
edition--and
local electrical code requirements.
This appliance
may be connected by means of
permanent "Hard Wiring" or "Power Supply Cord Kit."
When hard wiring, do not leave excess wire in range
compartment.
Excess wire in the range compartment
may not allow the access cover to be replaced
properly, and could create a potential electrical hazard
if wires become pinched. When using flexible conduit
or range cable, use flex connector or range cable strain
relief.
NOTE: Only use copper wire in connection
to terminal
block.
5.1 Models Requiring
Power Supply
Cord Kit
U,S, STYLE
3-Wire Cord Kit
The user is responsible for connecting the power
supply cord to the connection
block located behind the
back panel access cover.
This appliance
may be connected
by means of
permanent
"hard wiring""; flexible armored or
nonmetallic
shielded copper cable (when local code
allow it) or by means of a power supply cord kit.
NOTE: Electric Slide-in Range is shipped from factory
with 1 1/8" (2.9 cm) dia. hole as shown on figure 7 or 8.
if a larger hole is required, punch out the knockout.
Risk of fire or electrical
shock exists
if an incorrect size range cord kit is used, the
Installation
Instructions
are not followed,
or the
strain relief bracket
is discarded.
For mobile homes, new installations
or recreational
vehicles, use only a power supply kit designed for a
range at 125V/250V 50A recommended
(minimum
40A). Cord must have either 3 (when local code
permits grounding through neutral) or 4 conductors.
Terminal on end of wires must be either closed loop or
open spade lug with upturned ends. Cord must have
strain-relief
clamp. If a 50A circuit is used, a 50A power
cord must be used.
Do not loosen the nuts which secure
the factory=installed
range wiring
to terminal
block
while connecting
range. Electrical
failure
or loss of
electrical
connection
may occur.
Electrical
Shock
Hazard
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a grounded,
metallic, permanent wiring system, or a grounding
connector should be connected to the grounding
terminal or wire lead on the appliance.
Failure to do any of the above could result in a fire,
personal injury or electrical shock.
This appliance is manufactured with
the frame grounded by connection of a grounding
strap between the neutral power supply terminal and
the frame, if used in USA, in a new branch circuit
installation (1996 NEC), mobile home or recreational
vehicule, where local code do not permit grounding
through neutral (white) wire or in Canada; remove the
grounding strap from the frame and cut the other end,
near the neutral terminal. Connect the appliance in
usua_
manner.